TRSM0940
Service Procedures
|
Main Shaft Speed Sensor Removal and Installation
Main Shaft Speed Sensor Installation
Important:
Clean the mounting surface on the housing and
remove any burrs or sharp edges.
Important:
Lubricate the O-ring with Eaton Fuller silicone
71214 or equivalent.
1.
Use a smooth twisting motion; fully insert the Main
Shaft Speed Sensor in the rear Transmission Shift Bar
Housing bore
2.
Using a 3/8” socket, install the retaining bolt and
tighten 7–9 lb-ft (9–12 N•m.)
3.
Reconnect the Main Shaft Speed Sensor pigtail to the
Transmission Harness.
!
!