137
© 2017 Eaton. All rights reserved
2018.12.12
Shift Bar Housing Disassembly and Assembly
|
Service Procedures
TRSM0940
Shift Bar Housing Assembly
1.
Place the Shift Bar Housing upside down on a work
bench.
2.
Install the bar in the first bore of the Shift Bar Housing.
3.
Install the yoke lock screw and wire securely.
Note:
Brass covers must be used on vise teeth (if
used) to avoid damaging the Shift Bar Housing gasket
surface.
4.
Install the actuating plunger in the center boss bore.
5.
Install one 3/4” interlock ball in the rear boss top bore.
This ball rides between the 1st-Reverse and 2nd-3rd
Gear Shift Bars.
Note:
Coating the 3/4” interlock balls with grease will
help keep them in place in the bores.
6.
While holding the notched end of the bar, install the
2nd-3rd Gear Shift Bar in the housing boss middle
bore. Position the shift block on the bar between the
center and rear bosses.