
35
© 2017 Eaton. All rights reserved
2018.12.12
LAS/VAS Auxiliary Section Assembly and Installation
|
Service Procedures
TRSM0940
3.
Subtract the thickness of feeler gauges needed to fit in
between the Auxiliary Case and Auxiliary Counter Shaft
Covers from 0.100”. Use that number to pick a shim
that will allow for end-play of within 0.001”–0.005”.
Note:
Example: 0.042" of feeler gauges fit in between
Auxiliary Case and the Auxiliary Counter Shaft Bearing
Cover. Subtract 0.042" from 0.100" which equals
0.058". A shim of 0.052"–0.055” would be required for
the 0.003"–0.005” end-play. (If the required thickness
shim does not exist, use the closest undersized shim.)
4.
Install required shim into bearing bore, Install new
gasket between the Main Case and Auxiliary Case.
Summary of Contents for UltraShift PLUS Series
Page 2: ...1 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970...
Page 4: ......
Page 5: ...2019 07 11 2017 Eaton All rights reserved 4 TRSM0970 General Information...
Page 6: ...5 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970...
Page 7: ...2019 07 11 2017 Eaton All rights reserved 6 TRSM0970 General Information...
Page 8: ...7 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970...
Page 9: ...2019 07 11 2017 Eaton All rights reserved 8 TRSM0970 General Information...
Page 10: ...9 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970...