TRSM0940
Service Procedures
|
MHP/MXP/VHP/VXP Auxiliary Countershaft Installation
7.
Install Piston into the bore of the Range Cylinder Install
with the flat side of the piston facing rearward.
8
.
Secure the piston with the retaining nut, torque to
70-85 lb-ft (94.91-115.24 N•m).
Splitter Cylinder Installation
1.
With the Auxiliary Section still in the vice. Position the
Splitter Sliding Clutch on the Splitter Yoke fork and bar.
Engage into the Splitter Gear to maintain its position
2.
Install small O-ring in the Cylinder Housing Bore if pre-
viously removed