160
4. Electro-Hydraulic Control Unit
01/2018 Rev. 1
EA(B)O-6X06
Electro-Hydraulic Control Unit
Disassembly and Assembly
0122-18
Assembly
1. Assemble the new actuator tube repair assembly, tapping
lightly to the end but not giving the final tightening.
2. Install the plastic clamp observing the tube alignment.
3. Apply the specified torque.
0123-18
Air Purge of Brushless Motor Chamber
If all the oil in the system has been exhausted after the sup-
ply, it will be necessary to purge the confined air in the motor
chamber, following the steps below:
1. Fill the reservoir with oil to the maximum level.
0124-18