ICA-D212-725 (96)
Page 44 of 90
CHAPTER 96 – ELECTRICAL SYSTEM (96-00-00)
COPYRIGHT
2007 BY DART AEROSPACE LTD.
THIS DOCUMENT IS PRIVATE AND CONFIDENTIAL AND IS SUPPLIED ON THE EXPRESS CONDITION THAT IT IS NOT TO BE USED FOR ANY PURPOSE OR COPIED OR COMMUNICATED TO ANY
OTHER PERSON WITHOUT WRITTEN PERMISSION FROM DART AEROSPACE LTD.
Revision:
4
Date: 11.06.01
the overlay. Reapply the white slippage mark at
the top of the instrument.
96.5.3.3
After indicator alignment, verify
correct reading of the indicator by accomplishing
the following:
96.5.3.3.1
Remove pressure line from “T”
fitting at torque pressure transmitters (if two
transmitters installed) and attach pressure tester
to the transmitters.
96.5.3.3.2 Apply a pressure of 55.7 psi
(corrected for tester error) and verify both pilot
and copilot indicators read 55.7 ± 0.3 psi.
96.5.3.3.3 Reduce pressure and remove
pressure tester from pressure transmitters.
96.5.3.3.4 Reinstall pressure line on
transmitters (“T”).
96.5.3.3.5
Reapply the white slippage marks
to tops of instruments.
CAUTION
DO NOT EXCEED 65 PSI APPLIED
PRESSURE TO TRANSMITTERS.