ICA-D212-725 (26)
Page 9 of 11
CHAPTER 26 – FIRE PROTECTION (26-00-00)
COPYRIGHT
2007 BY DART AEROSPACE LTD.
THIS DOCUMENT IS PRIVATE AND CONFIDENTIAL AND IS SUPPLIED ON THE EXPRESS CONDITION THAT IT IS NOT TO BE USED FOR ANY PURPOSE OR COPIED OR COMMUNICATED TO ANY
OTHER PERSON WITHOUT WRITTEN PERMISSION FROM DART AEROSPACE LTD.
Revision:
5
Date: 12.06.20
NOTE: The manifold (1, Figure 26-3) must be free of dents and other mechanical damage, except as noted
below. It must be kept clear of dirt and debris internally and the discharge holes must be open.
NOTE: A smooth dent is acceptable in item (1) for clearance of jam nut on inner leg of tripod. Maximum dent
size is 1.5” (38.1 mm) parallel to tube and 0.25” (6.4 mm) in depth.
1. Manifold Assembly (D212-725-1-931)
2. Tube Assembly (D212-725-1-925)
3.
Container
Weld
Assembly
4.
Flexible
Hose
5.
Bracket
(D212-725-1-123)
6.
Indicator
7.
Bracket
(D212-725-1-923)
Figure 26-3.
Engine Fire Extinguisher