ICA-D212-725 (96)
Page 37 of 90
CHAPTER 96 – ELECTRICAL SYSTEM (96-00-00)
COPYRIGHT
2007 BY DART AEROSPACE LTD.
THIS DOCUMENT IS PRIVATE AND CONFIDENTIAL AND IS SUPPLIED ON THE EXPRESS CONDITION THAT IT IS NOT TO BE USED FOR ANY PURPOSE OR COPIED OR COMMUNICATED TO ANY
OTHER PERSON WITHOUT WRITTEN PERMISSION FROM DART AEROSPACE LTD.
Revision:
4
Date: 11.06.01
96.3.17.2.4 Place GCU TEST switch in
OVERLOAD position and verify that DC
GENERATOR light illuminates on Master Caution
Panel. Return GCU TEST switch to center
position, move GEN switch to RESET then ON
and verify that DC GENERATOR light
extinguishes.
96.3.18
Operational Check – Non-
Essential Buss
Operational check of nonessential bus system
should be performed immediately after completing
voltage control adjustment (paragraph 96.3.17).
96.3.18.1 Close NON-ESS BUS circuit
breaker. Set NON-ESS switch to MANUAL.
Check for 28 VDC on non-essential bus in
overhead console.
96.3.18.2
Set NON-ESS BUS switch to
NORMAL. Check for 28 VDC on non-essential
bus in overhead console.
96.3.18.3
Set GEN switch to OFF. Verify DC
GENERATOR caution light on caution panel is
illuminated. Check for zero volts on non-essential
bus.
96.3.18.4
Set NON-ESS BUS switch to
MANUAL. Check for 28 VDC on non-essential
bus.
96.3.18.5
Set GEN switch to ON. Verify DC
GENERATOR caution light on caution panel is
extinguished. Check for 28 VDC on non-essential
bus.
96.3.18.6
Set NON-ESS BUS switch to
NORMAL. Check for 28 VDC volts on non-
essential bus.
Figure 96-3.
Voltage Control Adjustment
Summary of Contents for ICA-D212-725
Page 2: ......
Page 19: ......
Page 47: ......
Page 55: ......
Page 71: ......
Page 73: ......
Page 75: ......
Page 95: ......
Page 121: ......
Page 137: ......
Page 149: ......
Page 249: ......
Page 251: ......
Page 325: ......
Page 327: ......
Page 473: ......
Page 475: ......
Page 531: ......
Page 581: ......
Page 707: ......
Page 729: ......