CHAPTER 26 – FIRE PROTECTION (26-00-00)
COPYRIGHT
2007 BY DART AEROSPACE LTD.
THIS DOCUMENT IS PRIVATE AND CONFIDENTIAL AND IS SUPPLIED ON THE EXPRESS CONDITION THAT IT IS NOT TO BE USED FOR ANY PURPOSE OR COPIED OR COMMUNICATED TO ANY
OTHER PERSON WITHOUT WRITTEN PERMISSION FROM DART AEROSPACE LTD.
Revision:
5
Date: 12.06.20
26.10.3.3 Connect tube assembly (2) to the
extinguisher output connector.
26.10.3.4 Remove the bare electrical wire
between the two electrical terminals and connect
the electrical wiring. (Refer to Chapter 98.)
26.10.4 Recharging
The 2241-009 Fire Bottle must be charged with 6
lbs of Halon 1301 by an approved facility.
26.11
PORTABLE FIRE EXTINGUISHERS
AND BRACKETS
Two hand-held, portable fire extinguishers are
installed in quick release brackets at the locations
illustrated in Figure 26-4. These extinguishers are
filled with monobromotrifluoromethane
extinguishing agent.
NOTE
Maintenance procedures for both fire
extinguishers and brackets are identical.
26.11.1 Removal
26.11.1.1 Release clamp (7, Figure 26-4) and
remove fire extinguisher.
26.11.1.2 Remove bolts (8) and washer (9).
Remove bracket (11) and washers (10).
26.11.2 Inspection
26.11.2.1 Inspect fire extinguisher (6, Figure 26-4)
for state of charge by weight (or by visual indicator, if
installed).
26.11.2.2 Record inspection on tag attached to
extinguisher (detail A).
26.11.2.3 Inspect bracket and attaching hardware
for obvious damage arid security of installation and
serviceability.
26.11.3 Repair
26.11.3.1 Recharge fire extinguisher as required
at a facility equipped and authorized to service
monobromotrifluoromethane type extinguishers.
26.11.3.2 Replace unserviceable bracket parts
and retaining hardware.
26.11.4 Installation
26.11.4.1 Position bracket (11, Figure 26-4) in
position with washers (10) between bracket and
mounting surface.
26.11.4.2 Install bolt (8) and washers (9). Tighten
bolts.
26.11.4.3 Open retaining clamp (7) and position
fire extinguisher in bracket. Close retaining clamp.
26.11.4.4 Verify bracket is securely installed in
helicopter and fire extinguisher is securely installed
in retaining bracket.
Summary of Contents for ICA-D212-725
Page 2: ......
Page 19: ......
Page 47: ......
Page 55: ......
Page 71: ......
Page 73: ......
Page 75: ......
Page 95: ......
Page 121: ......
Page 137: ......
Page 149: ......
Page 249: ......
Page 251: ......
Page 325: ......
Page 327: ......
Page 473: ......
Page 475: ......
Page 531: ......
Page 581: ......
Page 707: ......
Page 729: ......