Special instructions
14
4812273203.pdf
2017-08-25
Jump starting (24V)
Do not connect the negative cable to the
negative terminal on the dead battery. A spark can
ignite the oxy-hydrogen gas formed around the
battery.
Check that the battery used for jump
starting has the same voltage as the dead battery.
Turn the ignition and all power consuming equipment
off. Switch off the engine on the machine which is
providing jump start power.
Jump leads must have 24V
First connect the plus terminal (1) on the auxiliary
battery to the plus terminal (2) on the flat battery, then
connect the minus terminal (3) to a suitable earth point
(4) on the machine.
Start the engine on the power providing machine. Let it
run for a while. Now try to start the other machine.
Disconnect the cables in the reverse order.