Replacement Procedures
4.19
LCD/CAMERA MODULE
4-80 [CONFIDENTIAL] PORTÉGÉ X30W-J, dynabook V*/VZ*/VC* Series Maintenance Manual (960-941)
15.
Disconnect the
CAMERA HARNESS
(FPC portion)
from the connector on the
CAMERA MODULE.
16.
Remove the
CAMERA COV ASSY
from the LCD COVER ASSY.
17.
Remove the
SHUTTER SWITCH
from the CAMERA COV ASSY.
18.
Remove the
CAMERA MODULE
from the LCD COVER ASSY.
Figure 4-30 Removing the CAMERA MODULE (1)