Product description
3
Overview
3.1
Scope of delivery
The following items are included in the scope of
delivery (possible variations due to country-spe-
cific requirements and/or import regulations):
Units without a membrane-drying unit
Tornado 1 compressor, 230 V . . . . . . . . 5180-01
Tornado 1 compressor, 230 V . . . . . . . . 5180-03
Tornado 1 compressor, 100 – 110 V,
50 Hz / 100 – 127 V, 60 Hz . . . . . . . . . . 5180-02
Tornado 1 compressor, soundproof,
230 V . . . . . . . . . . . . . . . . . . . . . . . . . . . 5185-01
Tornado 2 compressor, 230 V . . . . . . . . 5280-01
Tornado 2 compressor, 230 V . . . . . . . . 5280-03
Tornado 2 compressor, soundproof,
230 V . . . . . . . . . . . . . . . . . . . . . . . . . . . 5285-01
– Compressor
– Fabric reinforced hose
– Hose nozzle
– Hose clamp
– Vibration dampers
– Cable ties
– Mains cable
– Installation and operating instructions
– Appliance log book
Unit with membrane drying unit
Tornado 1 compressor with mem-
brane drying unit, 230 V . . . . . . . . . . . . 5182-01
Tornado 1 compressor with mem-
brane drying unit, 230 V . . . . . . . . . . . . 5182-03
Tornado 1 compressor with mem-
brane drying unit, 100 - 110 V, 50 Hz /
100 - 127 V, 60 Hz . . . . . . . . . . . . . . . . 5182-02
Tornado 1 compressor with mem-
brane drying unit, soundproof, 230 V . . 5186-01
Tornado 2 compressor with mem-
brane drying unit, 230 V . . . . . . . . . . . . 5282-01
Tornado 2 compressor with mem-
brane drying unit, 230 V . . . . . . . . . . . . 5282-03
Tornado 2 compressor with mem-
brane drying unit, 230 V . . . . . . . . . 5282100029
Tornado 2 compressor with mem-
brane drying unit, soundproof, 230 V . . 5286-01
– Compressor
– Fabric reinforced hose
– Hose nozzle
– Hose clip
– Vibration dampers
– Cable ties
– Mains cable
– Installation and operating instructions
– Appliance log book
– Collector tray
3.2
Optional items
The following items can optionally be used with
the unit; these items do not bear the CE mark:
Pressure reducer . . . . . . . . . . . . . . . 6040-992-00
Sterile filter . . . . . . . . . . . . . . . . . . . 1640-981-00
Wooden cabinet for types:
5180, 5280, 5182, 5282 . . . . . . . . . 5150-500-00
3.3
Wear parts and replacement
parts
The following working parts must be replaced at
regular intervals (refer also to "Maintenance");
these articles do not bear the CE mark:
Air intake filter . . . . . . . . . . . . . . . . . 5180-982-00
Fine filter . . . . . . . . . . . . . . . . . . . . . 1610-121-00
Sterile filter . . . . . . . . . . . . . . . . . . . 1640-981-00
Sinter filter . . . . . . . . . . . . . . . . . . . . 1650-101-00
Cup seal repair set . . . . . . . . . . . . . 5180-981-00
Any repairs exceeding routine mainte-
nance may only be carried out by quali-
fied personnel or our service.
Information about replacement parts is
available from the portal for authorised
specialist dealers at:
www.duerrdental.net.
If the mains cable of this unit is damaged,
it must be replaced by an adequate
mains cable (H05VV-F, or abbreviation
60227 IEC 53, minimum cable cross-sec-
tion 1 mm
2
).
Product description
9000-610-60/02 1909V007
7
EN