4-12
CHAPTER 4 FINE-ADJUSTMENT AND OPTION SETTING
● Before adjusting the glue amount, make sure that the hot melt glue is completely
melted.
● The temperature around the glue tank is very high. Be careful when you adjust the
glue amount.
● Be careful not drop the supplied tools inside the glue tank.
●
High voltage of electricity supplied to the glue tank may cause an electric shock. Be
careful.
1-9 Adjusting the Nipping Station
When the spine of the finished booklet is round or when there is some space between the book block
and the cover, you may need to adjust the height of the nipping station. Check the finished booklets
and adjust the height of the nipping station if necessary.
Nipper level
adjustment access
1.
Open the nipper level adjustment
access.
2.
Move the adjustment lever seeing the
scale.
Adjustment lever
Fine-adjustment range:
–1.5 to +0.5 mm (–0.06 to +0.02 inch)
Base position: -0.5
Turning the lever to the + direction will raise
the height of the nipping station.
Turning the lever to the – direction will
lower the height of the nipping station.
3.
Close the nipper level adjustment
access.
Summary of Contents for DPB-500
Page 15: ...Chapter 1 BEFORE OPERATION...
Page 36: ...1 22 CHAPTER 1 BEFORE OPERATION Memo...
Page 37: ...Chapter 2 PREPARING FOR OPERATION...
Page 59: ...Chapter 3 STARTING BINDING OPERATION...
Page 86: ...3 28 CHAPTER 3 STARTING BINDING OPERATION Memo...
Page 87: ...Chapter 4 FINE ADJUSTMENT AND OPTION SETTING...
Page 116: ...4 30 CHAPTER 4 FINE ADJUSTMENT AND OPTION SETTING Memo...
Page 117: ...Chapter 5 CLEANING THE UNIT...
Page 127: ...Chapter 6 TROUBLESHOOTING GUIDE...
Page 145: ...Chapter 7 APPENDIX...
Page 147: ...7 3 CHAPTER 7 APPENDIX Memo...
Page 148: ...11H 92832 0 09050000D This manual is printed on recycled paper to help protect the environment...