4-18
CHAPTER 4 FINE-ADJUSTMENT AND OPTION SETTING
3-4. Setting the Glue Tank Temperature
The appropriate temperature varies depending on the hot melt glue you are using. Check the
appropriate temperature for the hot melt glue.
Default setting: 150°C/302°F
Setting range: 100 to 180°C/212 to 356°F
1.
Press the next or previous button on the option screen to display the screen
below.
Example
130
12
0
100
Next Button
Previous Button
140
Glue Tank Temperature
0
2.
Press
or
to change the glue tank temperature.
3.
Press the next or previous button to display other option screen.
3-5. Setting the Standby Mode
If you do not operate the machine for the specified time, the machine enters automatically to the
standby mode. You can specify the time on the screen below.
During the standby mode, the heater will be kept at a certain temperature.
Default setting: 1:30
Setting range: 0:00 (OFF) to 5:00
1.
Press the next or previous button on the option screen to display the screen
below.
1:30
Example
Time to enter
the standby mode
Previous Button
Next Button
3:0
0
1:00
5:00
Summary of Contents for DPB-500
Page 15: ...Chapter 1 BEFORE OPERATION...
Page 36: ...1 22 CHAPTER 1 BEFORE OPERATION Memo...
Page 37: ...Chapter 2 PREPARING FOR OPERATION...
Page 59: ...Chapter 3 STARTING BINDING OPERATION...
Page 86: ...3 28 CHAPTER 3 STARTING BINDING OPERATION Memo...
Page 87: ...Chapter 4 FINE ADJUSTMENT AND OPTION SETTING...
Page 116: ...4 30 CHAPTER 4 FINE ADJUSTMENT AND OPTION SETTING Memo...
Page 117: ...Chapter 5 CLEANING THE UNIT...
Page 127: ...Chapter 6 TROUBLESHOOTING GUIDE...
Page 145: ...Chapter 7 APPENDIX...
Page 147: ...7 3 CHAPTER 7 APPENDIX Memo...
Page 148: ...11H 92832 0 09050000D This manual is printed on recycled paper to help protect the environment...