2-4. Nipping Problem
Symptom
Cause
Solution
The nipping section
does not go up.
The nipping delay time is set to "0."
Change the setting on the touch panel
screen. ( p.4-15)
"Without a cover" (pad binding) is
selected.
Check the setting on the touch panel
screen. ( p.2-12)
The nipping section
does not go down.
During a pad binding operation, the glue
applied to the spine sticks to the nipping
surface.
Remove the spine from the nipping
surface little by little and change the
nipping delay time. ( p.4-15)
The cover is not
smoothly fed to the
nipper.
The cover does not go to the nipper
guide smoothly because of a curled
edge.
Use the supplied guide. ( p.3-23)
The secondary feed roller pressure is
low.
Adjust the secondary feed roller
pressure. ( p.3-10)
The nipper guides width is shorter than
the cover width.
Adjust the position of the nipper guides
on the touch panel screen. ( p.4-5)
Summary of Contents for DPB-500
Page 15: ...Chapter 1 BEFORE OPERATION...
Page 36: ...1 22 CHAPTER 1 BEFORE OPERATION Memo...
Page 37: ...Chapter 2 PREPARING FOR OPERATION...
Page 59: ...Chapter 3 STARTING BINDING OPERATION...
Page 86: ...3 28 CHAPTER 3 STARTING BINDING OPERATION Memo...
Page 87: ...Chapter 4 FINE ADJUSTMENT AND OPTION SETTING...
Page 116: ...4 30 CHAPTER 4 FINE ADJUSTMENT AND OPTION SETTING Memo...
Page 117: ...Chapter 5 CLEANING THE UNIT...
Page 127: ...Chapter 6 TROUBLESHOOTING GUIDE...
Page 145: ...Chapter 7 APPENDIX...
Page 147: ...7 3 CHAPTER 7 APPENDIX Memo...
Page 148: ...11H 92832 0 09050000D This manual is printed on recycled paper to help protect the environment...