G 3800 X036 Operation Manual
August 2006
60
© 2006 Carlo Gavazzi Industri A/S. All rights reserved
Parameter
Description
Active detector
Disable address
Enter an address or a flag whose activation (“1”-signal) will prevent the
detector to cause an alarm. This feature may be used to have more alarm
zones, when the alarm is armoured by the Manual Armouring.
Manual armouring
Door-lock armouring
Code lock armouring
Armouring delay
Determines the delay, from start of the alarm, until the the alarm
surveillance becomes active. The delay is used to cope with the
situation where a detector is activated, while the alarm is switched on.
Eg. The Alarm switch for start and stop is located in the hall, and the
frontdoor is equipped with an alarmdetector. Time should be set long
enough, that a person may start the alarm and leave through the door,
without causing an alarm.
De-armouring delay
Determines how many seconds may pass from an alarm has occured
untill the alarm siren is activated. The time is used to cope with the
situation, where the rightfull owner actually causes an alarm, by entry.
Eg. The Alarm switch for start and stop is located in the hall, and the
frontdoor is equipped with an alarm detector.
Time should be set long enough, that a person may open the door, walk
across the hall, and stop the alarm.
Alarm siren
Siren time
Enter for how long time the alarm output is to remain activated when an
alarm occurs. It is limited from 0 and 60 min.
The entered value is automatically adopted by the Common siren.