© 2006 Carlo Gavazzi Industri A/S. All rights reserved
61
G 3800 X036 Operation Manual
August 2006
Parameter
Description
Flash when Alarm
Select this to setup the 'Visual' alarm effects. This allows you to select which
channels are to flash while the Siren is activated.
Only when selected, the "Flash interval" entry and the "Flash addresses" button
are visible.
Flash Interval
Here you can enter the switch on/off time span of the flashing alarm signals. The
option “Flash when Alarm” must be switched on.
The value can lie between 0 and 60 s. Please note that flash intervals below 2
seconds may turn out inaccurately because of the cycle time. When the value 0
is entered, flashing takes place at the fastest possible rate.
Flashing Channels
Click on this button to open the address matrix to select the addresses which
are to flash upon an alarm.
Only shown when "Flash when alarm" is selected.
Alarm signal
Alarm signal delay
With this setting you can determine the time which is to elapse from the alarm
siren is activated till the alarm signal is activated. The value can lie between 0
and 10 min.
Enable Simulated
Select this option to make an automatic Playback of the adresses selected for
occupation when
Record/Playback.
Alarm is armed
Selection of
Record/Playback
Recording
The selection of Record/Playback is available on most of the objects.
The recording only takes place when the Intruder-alarm is in active.
When selected for Record / Playback, the object’s output status will be record-
ed at every 3 minutes intervals. The recording operates like an endless ‘tape-
loop’ running over one week.
The recorded data are stored permanently once every 24 hours just before mid-
night, to continuously renew the record-history.
Playback takes place, when the Intruder-alarm is started and the "Enable
Simulated occupation" is selected. The recorded data are used to activate the
objects in the same sequence as recorded.
If no records have been made for a certain time period while playback, the
objects will keep their last set on/off status.
The Playback activation of the objects, is a set – reset operation sent to the
objects, which is similar to a normal Manual activation.
When turning off the intruder alarm, the last set status will still remain on the
objects.