Time characteristics
On- Off-delay timer, started by pulse.
Delay On
Delay Off
The on-delay starts upon deactivation of the input. After elapse of the On-delay, the Output turns on, and the
Off-time is started.
After elapse of the Off-time the output switches off again.
Repeating the activation-pulse while the output is Off will restart the On-delay.
Repeating the activation-pulse while the output in On will restart the Off-time.
Parameter
Description
Enabled by address
Entering of an additional adress (A1..P8) or flag which will also enable the timer
function. To prevent locking, the channel assigned to the timer itself must not be
used.
If the additional signal is an impulse, select the option Activation by pulse.
Recycler
Configuration window for recycler
Parameter
Description
Timer function
To select the Recycler function, select “Recycler”
On-time
Entering of the time (1 s to 99 h, 59 min, 69 s) for which the output is On during
recycling
Off-time
Entering of the time (0 s to 99 h, 59 min, 59 s) for which the output is Off during
recycling
Enabled by address
Entering of an additional channel or flag which will also enable the recycler. To
prevent locking, the channel assigned to the recycler itself must not be used.
IN
OUT
G 3800 X036 Operation Manual