33
Service Manual for Proofer Oven with Touch Screen Controls (TSC)
4. Remove old filter by rotating cartridge clockwise
slowly until pressure starts to release, stop and let
pressure and excess water drain through pressure
release hose. Once water has stopped draining,
continue turning to the left and pull downward.
Pressure
Relief
Hose
Inlet
Strainer
Housing
Quick
Disconnect
Figure 41: Water Filter
5. Install new filter by removing sanitary cap from
top of new Cartridge, insure two black O Rings
are in place, then lift up into filter head and rotate
Cartridge 1/4 turn counter clockwise until it comes
to a complete stop.
6. Remove Inlet Strainer by loosing Hex cap on Inlet
strainer Housing.
Hex
Cap
Strainer
Screen
Figure 42: Inlet Strain & Screen
7. Remove and flush the strainer screen with warm
water.
8. Replace strainer screen and Hex Cap.
9. Flush 2 gallons of water through the new filter
before using proofer to purge air from filter.
10. Remove hose from bottom of proofer by removing
red retention clip then push in quick disconnect
fitting and pull hose out.
11. Place hose into a bucket and turn on water. It will
take a minute for the filter to fill before water flows
out of hose into container.
Red
Retention
Clip
Figure 43: Purging Air From Water Filter
12. Once filter is flushed with 2 gallons of water, turn
off water supply again, insert hose into quick
disconnect, replace red retention clip by slightly
pulling hose.
13. Turn water supply on and check for leaks at
connection fittings and Inlet Strainer Housing Hex
Cap.
14. Reconnect Wall Brackets if installed.
15. Turn on power to Proofer Oven using the Touch
Screen Display