24
Owner's Manual for Duke Flexbake 5
TM
Proof and Bake Oven with WiFi Connectivity
BULB MOUNTING DETAILS
Turn counter-clockwise.
Remove bulb cover.
Lamp Holder
Assy.
G4 12V
Flat Lens
58mm
(502794)
Gasket -
Lens 58mm
(502795)
10W (Max.) Lamp
12V Halogen
G-4 (Bi-Pin)
(512495)
Figure: Halogen Lamp Assembly
CAUTION
DO NOT TOUCH LIGHT BULBS WITH BARE HANDS AS OIL/FINGERPRINTS
WILL SHORTEN THE LIFE OF THE BULB. USE A CLEAN GLOVE OR CLOTH TO
HANDLE BULBS.
1. Disconnect external all poles mains supply and allow to cool.
2. Remove the light lens and gasket by turning it counter clockwise.
3. Remove the burned out bulb.
4. Using clean gloves or a cloth, install the new lamp bulb (Halogen Lamp G4, 12 V, 10 W
Maximum) into the lamp holder.
5. Replace light lens and gasket ensuring it is fully seated and tightened or leaks will occur.
LAMP BULB REPLACEMENT