14
Owner's Manual for Duke Flexbake 5
TM
Proof and Bake Oven with WiFi Connectivity
INSTALLATION-continued
Wall
DETAIL A
SCALE 3 : 1
Wall Mounting
Bracket
Hole Drilled In Wall
For Fixing Bracket
Wall
STEP 4
Insert the wall anchors into the holes.
STEP 5
Position the Wall Mounting Brackets against the wall.
STEP 6
Insert the screws into the Wall Mounting Bracket.
STEP 7
Ensure that the Brackets are firmly against the wall and
tighten the screws securely.
TECHNICAL DESCRIPTION AND APPLICATION NOTES FOR DUKE FLEXBAKE 5
TM
PROOF AND BAKE OVEN BACKFLOW PREVENTER SYSTEM
Check with your local authority having jurisdiction regarding approvals for connecting the Duke Flexbake 5
TM
Proof
and Bake Oven to a potable water supply before making any plumbing connections. Plumbing code requirements
vary, but European Union (CE) and other jurisdictions require a backflow prevention device that is factory-installed
or available as a kit (P/N 600187). The backflow prevention device used on Duke Flexbake 5
TM
Proof and Bake Oven
protects water supply systems by preventing the reverse flow of non-potable water into the potable domestic water
system. The device consists of two independently acting check valves, internally force-loaded to a normally closed
position and designed/constructed to operate under intermittent or continuous pressure conditions. The two main
components of the Duke backflow preventer system are:
• Dual Check Valve type backflow preventer that conforms to ANSI/ASSE standard #1024 and is CSA standard B64.6
certified.
• Inlet water strainer equipped with 100-mesh screen and installed up stream of the backflow preventer. The
screen is conveniently located below the backflow preventer, for easy access during cleaning/replacement.
INSTALLATION OF WALL-BRACKETS
NOTE: Verify interconnections and function prior to installing optional wall
brackets
STEP 1
Mount the Wall Mounting Brackets with screws
provided with the Proof and Bake Oven.
STEP 2
Extend the Wall Mounting Bracket towards the wall
by sliding it through the slot provided but do not tighten the
screws.
STEP 3
Mark the Wall and Drill holes for the wall anchors.