![Drone Amplified DJI M600 Operational Manual Download Page 41](http://html1.mh-extra.com/html/drone-amplified/dji-m600/dji-m600_operational-manual_2532780041.webp)
Ignis Operations Manual (DJI M600 Variant)
Drone Amplified
significant
fire risk
. In addition, the ignition spheres can “jump” a significant amount when
igniting, so make sure a significant area is clear if performing live ignitions.
If you do not want to ignite ignition spheres, we recommend removing the needles for
this test to make sure that the ignition spheres cannot be injected.
Start continuous drops by first moving S3 on the control bar into the upward position to
arm Ignis. Then press the Start button in the Drone Amplified Android app.
During this process, verify the following:
•
The puncture motor moves (see Section 4.1.13).
•
The A and B hatches open without obstruction.
•
Ignition spheres are loaded and punctured in both A and B (if performed with ignition
spheres).
•
Fluid is injected in both A and B.
•
The app status indicates dropping.
This process will perform injections on both A and B sides until stopped.
4.1.22 Stop Dropping
Stop Dropping
:
Disarmed, Ignis Stopped
Press the Stop button in the app to stop dropping. To also disarm Ignis in order to
prevent accidentally starting again, move the Arm/Disarm switch (S3) on the control bar
into the disarm position (down and away from the user), as shown in Figure 4. Further,
make sure that all motions of the system stop and that the app indicates ready. Note that
the stopping process can take 5-10 seconds while the system purges any additional ignition
spheres and performs a calibration process.
4.1.23 Check Ignis Status in App
Check Ignis Status in App
:
Disarmed by Control Bar
Verify that the status message in the app’s flying screen indicates Ignis has no errors.
4.1.24 Create Geofence
Create Geofence
:
Created
Last Updated March 12, 2020
Page 41