Functions (water) - 8
Version 1.36
02/2004
I.
Disassembly of the water inlet valve
1. Close the faucet and remove the external water supply hose. (water inside!)
2. Pour half a cup of hot water (in order to remove water from the silicon hose attached to the
inlet valve). Place the hose upright during the process.
3. Unplug the power cord.
4. Remove the lid of the tank (1 Torx 15 screw).
5. Remove the silicon water hose from the valve.
6. Remove the wiring from the valve (2 connectors).
7. Remove the valve. (2 Torx 15 screws)
8. Disassemble in reverse order. Ensure that :
- the correct flow restrictor is used
- the sealing ring of the external water supply hose is placed correctly
- air is allowed to escape from the external water supply hose.
1
3
2
4
5
6
7