Faults -1
Version 1.36
02/2004
3.1 Indications
Machine status and errors are communicated by means of LED indicators (On/Off/Blinking). It is also possible
to display the last error detected by connecting the service device. The following malfunctions may be displayed
directly after the service device is connected. (See chapter 4 page 1 for connection of the service device)
Message
Condition
Measure
Heater switched on too long
The heater remained on for more
Safety device in the element
than 840 seconds
connector has been activated
Check the heating element and
relay
Boiler temp too high
The set boiler temperature is exceeded
Check/replace the NTC sensor
by more than 4°C/39°F
Check the relay
Boiler level low too long
Boiler low level detected for more than
Check/replace sieve, inlet valve
25 sec or 120 sec after the dispenser
and check if a tube is bent,
is switched on (water tank is not empty).
squeezed or partly disconnected
Cooling temp too long high
Cooling compartment temperature
Check/replace the coffee pack,
exceeds 10°C/50°F for more than
it may have been far too warm
3 hours
Check/replace the NTC sensor,
Peltier element and cooling fan
Cooling temp too low
Cooling compartment temperature
Check/replace the coffee pack,
dropped under 1°C /34°F
it may still be frozen
Check/replace the NTC sensor
Eeprom broken or not build in Data cannot be retrieved
Check/replace Eeprom (see note
(default settings will be used instead)
on pages of section 5K)
Eeprom (re)programmed
Data cannot be retrieved immediately,
but within 3 attempts (retry on error)
Inlet valve too often open
More than 500 ml16.9 fl oz water was
Check/replace the inlet valve
supplied in the stand-by mode
Bad dosing!!
B2 pulse < 6.6 ms or > 7.2 ms
Check/replace the coffee pack
1.
Coffee empty LED
2 . Water tank empty LED
3 . Boiler temperature low LED
4 . Cooling temperature LED
5 . Power LED
1
2
3
I/O
REPLACE COFFEE PACK
REFILL WATER TANK
WARMING UP, PLEASE WAIT
COFFEE
HOT WATER
4
5
Machine status/error indications
Remark concerning Water tank Empty LED :
If the fixed water connection is installed this
indicator does not refer to the water tank, but to an interrupted water supply to the boiler. It will
blink in case of an malfunction.
Summary of Contents for Cafitesse 50
Page 4: ...Version 1 36 02 2004 ...
Page 20: ...Version 1 36 02 2004 ...
Page 30: ...Version 1 36 02 2004 ...
Page 38: ...Programming 8 Version 1 36 02 2004 4 3 Programming flow chart service device ...
Page 56: ...Version 1 36 02 2004 ...
Page 64: ...Version 1 36 02 2004 ...
Page 78: ...Version 1 36 02 2004 ...
Page 80: ......
Page 94: ...Version 1 36 02 2004 ...
Page 95: ...Version 1 36 02 2004 6 Preventive Maintenance Contents 02 2004 Not available ...
Page 96: ...Version 1 36 02 2004 ...
Page 102: ...Version 1 36 02 2004 ...
Page 103: ...Version 1 36 02 2004 8 Service Information Bulletins Contents 02 2004 Not available ...
Page 104: ...Version 1 36 02 2004 ...
Page 105: ...Version 1 36 02 2004 9 Modification Instructions Contents 02 2004 Not available ...
Page 106: ...Version 1 36 02 2004 ...