Functions (Machine control) - 7
Version 1.36
02/2004
Connector/pin
Voltage
Remarks
11-1
0/5V
Cold water empty detection (0V=Water/5V=No water)*
11-2
GND
Cold water empty detection GND*
11-3
24V
Cold water valve power supply
11-4
0/24V
Cold water valve return (0V=On/24V=off)
11-5
GND
Not connected
11-6
GND
Not connected
11-7
GND
Not connected
12-1
-
Not connected
12-2
-
Not connected
12-3
-
Not connected
12-4
-
Not connected
12-5
-
Not connected
12-6
-
Serial out service device
12-7
-
GND
12-8
-
Not connected
12-9
-
Serial in service device
13-1
19,75V
Dosing coil power supply
14-1
-
Dosing coil return
15-1
0/11V
Peltier element (0 V = On / 11 V = 0ff)
16-1
0/11V
Peltier element return (0 V = On / 11 V = 0ff)
17-1
5V
Power supply
17-2
-
Dataline coin mechanism
17-3
-
Clockline coin mechanism
17-4
-
GND
18-1
0 V
B2 Current -
18-2
1,15 V
B2 C
18-3
0 / 5 V
B2 coil control (Off=0V/On=5V)
(*Not connected when the connector of the fixed water connection is plugged in)
Summary of Contents for Cafitesse 50
Page 4: ...Version 1 36 02 2004 ...
Page 20: ...Version 1 36 02 2004 ...
Page 30: ...Version 1 36 02 2004 ...
Page 38: ...Programming 8 Version 1 36 02 2004 4 3 Programming flow chart service device ...
Page 56: ...Version 1 36 02 2004 ...
Page 64: ...Version 1 36 02 2004 ...
Page 78: ...Version 1 36 02 2004 ...
Page 80: ......
Page 94: ...Version 1 36 02 2004 ...
Page 95: ...Version 1 36 02 2004 6 Preventive Maintenance Contents 02 2004 Not available ...
Page 96: ...Version 1 36 02 2004 ...
Page 102: ...Version 1 36 02 2004 ...
Page 103: ...Version 1 36 02 2004 8 Service Information Bulletins Contents 02 2004 Not available ...
Page 104: ...Version 1 36 02 2004 ...
Page 105: ...Version 1 36 02 2004 9 Modification Instructions Contents 02 2004 Not available ...
Page 106: ...Version 1 36 02 2004 ...