Functions (water) - 3
Version 1.36
02/2004
8. Reinstall the water inlet hose, the heating element connector and the
boiler wiring
connector
.
9. Put the drain hose back in place and reinstall the left cover.
10. Calibrate the coffee valve. This can be done by means of button programming or the
service device (in case of the latter please do so before step 9).
Enter the button programming mode. Place a measuring cup under the coffee outlet.
Press the coffee pot button and keep it pressed until 0,5 litre/60.9 fl oz has
been dispensed. The dispenser will calculate the flow of the valve.
Cancel the programming mode.
In case of the service device you will find the calibration in the installation sub-menu.
Press [1] to dispense 0,5 litre/60.9 fl oz and press [0] to stop.
7. Connect the overboil hose to the tube.