Functions (dosing) - 3
Version 1.36
02/2004
Door mount
Sealing
Retaining
screws
Retaining
screws
Dosing coil assembly
Insulating covers
12.
Open the door of the cooling compartment
and remove the retaining screws of the mount
of the door. Remove the door mount and the
sealing
13.
Remove the left and right thermal insulation.
10. Tilt the complete cooling compartment a little
towards you.
11.
Lift the complete cooling compartment
assembly (including the operation panel)
gentlyfrom the machine, guide the wiring
from the control PCB carefully through the
opening in the frame to prevent damage
to the wiring.