background image

LA-3 SERIES 

Automatic And Pour-Over Coffee Brewers 

 

1034505, 1034521 

Automatic Brewer, Left Hand

 

1034506, 1034520 

Automatic Brewer, Right Hand

 

 

1034516 

Pour-Over Brewer, Left Hand

 

1034517 

Pour-Over Brewer, Right Hand

 

 

 

 

 

20333 S. Normandie Ave., CA 90502 

800-421-6860  

  310-787-5444  

  Fax 310-787-5412 

USA –E-mail: [email protected] 

INT’L E-mail: [email protected] 

Website: brewmatic.com 

 
 
FM CS110 A 6/28/07 

Summary of Contents for 1034505

Page 1: ...506 1034520 Automatic Brewer Right Hand 1034516 Pour Over Brewer Left Hand 1034517 Pour Over Brewer Right Hand 20333 S Normandie Ave CA 90502 800 421 6860 310 787 5444 Fax 310 787 5412 USA E mail brew brewmaticusa com INT L E mail brew_equip brewmaticusa com Website brewmatic com FM CS110 A 6 28 07 ...

Page 2: ...matic Brewers Page 5 1034516 1034517 LA 3 Pour Over Brewers Page 6 Troubleshooting Guide Pages 7 13 Parts Diagrams And Parts Lists Pages 14 24 6003093 Element Pan Assembly W PTC Black Page 14 1034505 1034506 1034520 1034521 LA 3 Automatic Brewers Pages 15 18 Tank Assembly LA 3 Brewers Pages 19 20 1034516 1034517 LA 3 Pour Over Brewers Pages 21 24 ...

Page 3: ...design of this appliance Any modification or alteration to the appliance may create a fire hazard may create a risk of personal injury may void the safety listings and may void the warranty Plumbing connections All plumbing connections to water supply lines and drains should be performed by a licensed plumber complying with all applicable plumbing codes having jurisdiction Electrical connections W...

Page 4: ...red 30 psi min 80 psi max 30 psi min 80 psi max 30 psi min 80 psi max 30 psi min 80 psi max None required None required Water Connection 1 4 flared fitting Flared nut supplied 1 4 flared fitting Flared nut supplied 1 4 flared fitting Flared nut supplied 1 4 flared fitting Flared nut supplied None None Listings ETL safety sanitation ETL safety sanitation ETL safety sanitation ETL safety sanitation ...

Page 5: ...Page 5 WIRING DIAGRAM 1034505 1034506 1034520 1034521 LA 3 Automatic Coffee Brewers 120V Auto 120 240V Auto ...

Page 6: ...Page 6 WIRING DIAGRAM 1034505 1034506 1034520 1034521 LA 3 Automatic Coffee Brewers 120V PO ...

Page 7: ...g Worn or damaged wiring may cause malfunctions and premature component failures Replace any wires that have loose connections damaged insulation or show evidence of overheating When repairing or replacing internal electrical wiring in part or in whole use only terminals and wires with the same rating gauge and insulation covering Adjusting the faucet flow beyond factory recommended settings could...

Page 8: ...id valve Replace it if necessary Automatic models only If present check any in line water filters check valves or shut off valves for proper operation or blockage Automatic models only 3 The coffee brewer will not heat The brew cycle and warmers work The water for brewing is cold Test the thermostat Replace it if necessary Test the thermostat sensor Replace it if necessary See 7 Test the immersion...

Page 9: ...ose damaged or overheating wires or terminals Repair or replace wiring as necessary Inspect the warmer elements for damage Replace it if necessary Inspect the immersion element for damage Replace it if necessary 7 The brewing temperature is either too hot or too cold Make sure that the thermostat sensor is inserted all of the way into the well Adjust or replace the thermostat Turn the adjustment s...

Page 10: ...ubing and siphon fittings Inspect the reservoir and reservoir tubing for blockage Make sure the tank cover is in place correctly and that the gaskets are in good condition Do not over tighten the tank lid hold down screw See page 18 Item 16 The screw should be just tight enough to seal the tank Over tightening the screw can deform the tank lid causing water leaks and can also change the angle of t...

Page 11: ...ently Check to make sure the internal wiring is correct Inspect for loose damaged or overheating wires or terminals Repair or replace wiring as necessary Test the voltage supply The voltage supplied should match the voltage requirement on the electrical nameplate Test the wall receptacle for correct polarity Use only original or authorized replacement parts 14 Water leaks from the bottom of the co...

Page 12: ... chatter or howl Automatic models only Check to make sure the internal wiring is correct Inspect for loose damaged or overheating wires or terminals Repair or replace wiring as necessary The coffee brewer should be connected to a cold water line only Water supply lines should not touch the coffee brewer or counter top Position the supply lines so that they do not touch anything Test the incoming w...

Page 13: ...the coffee Too much coffee or coffee that is ground too fine may slow the flow of the water through the coffee Make sure that the paper filter being used is correct for this type of coffee brewer Two paper filters may have been used accidentally Use only one filter per brew cycle Fine grind coffees and water softening systems may affect the way the water flows through the brew cone and coffee and ...

Page 14: ...ment 7 9905350 Eyelet Element Pan 8 9301106 Washer 10 x 049 Thick S S 9 9918270 Rivet Tubular Aluminum The PTC or Positive Temperature Coefficient element is a self regulating element that adjusts its temperature to maintain a consistent preset level The result is an even beverage temperature regardless of the beverage level in the decanter Another feature of this element is its ability to operate...

Page 15: ...Page 15 PARTS DIAGRAM EXTERNAL VIEW 1034505 1034506 LA 3 Automatic Coffee Brewers ...

Page 16: ...per Assy 17 1034109 Top Cover 18 1034147 Grid Pour In Plastic Black 19 1034148 Cover Grid Plastic Black 20 9916176 Plug Snap 7 8 21 1034192 Cover Back Center 22 9903435 9903583 Cord Lead 120V Cord Lead 220V 23 9902329 Bushing Strain Relief 24 6000011 Nut Hex 1 2 26 6000637 Reservoir Plastic Brown 27 1040684 Facia Bottom Black 33 9001229 Screw Machine 6 32 x 7 16 34 9914285 Nut Tinnerman 84 9906103...

Page 17: ...Page 17 PARTS DIAGRAM INTERNAL VIEW 1034505 1034506 1034520 1034521 LA 3 Automatic Coffee Brewers ...

Page 18: ...9920130 Fitting Tee 1 4 Tube x 1 4 Tube x 1 4 Tube 41 9914173 Nipple Hex Brass 1 4 Pipe 42 6000747 Bushing Reducer 1 4 Flare x 1 2 Straight Pipe x 1 4 Pipe 43 9001208 Screw Machine 8 32 x 5 8 44 9303104 Washer Lock With Internal Tooth 8 45 9201145 Nut Hex 8 32 S S 46 9001258 Screw Machine 10 32 x 1 4 47 1031320 Spray Head Brewer 48 9202120 Nut Hex 1 8 27 x 1 16 Thick 49 9907223 Gasket S S 13 32 ID...

Page 19: ...Page 19 PARTS DIAGRAM TANK VIEW LA 3 Automatic and Pour Over Coffee Brewers ...

Page 20: ...P Automatic models only 10 6000826 Fitting Elbow Soldered 11 6000818 Nut Hex 3 8 Straight pipe 12 9915155 O Ring 1 OD x 864 ID x 07 Thick 13 9202123 Nut Hex 1 2 20 5 16 Thick 14 9915110 O Ring Spray Head 487 ID x 693 OD 15 1010254 Gasket Tank 16 9001261 Screw Machine 10 32 x 1 1 8 17 1034125 Adjustment Plate 18 1034009 Bracket Assembly Tank Lid 19 9920436 Thermostat Hi Heat Limiter 120v 20 9201152...

Page 21: ...Page 21 PARTS DIAGRAM EXTERNAL VIEW 1034516 1034517 LA 3 Pour Over Coffee Brewers ...

Page 22: ...4 Pilot Light 125v Green Terminal Connector 17 1034109 Top Cover 18 1034147 Grid Pour In Plastic Black 19 1034148 Cover Grid Plastic Black 20 9916176 Plug Snap 7 8 21 1034192 Cover Back Center 22 9903435 Cord Lead 23 9902329 Bushing Strain Relief 26 6000637 Reservoir Plastic Brown 27 1040684 Facia Bottom Black 33 9001229 Screw Machine 6 32 x 7 16 34 9914285 Nut Tinnerman 87 9003141 Screw Machine 6...

Page 23: ...Page 23 PARTS DIAGRAM INTERNAL VIEW 1034516 1034517 LA 3 Pour Over Coffee Brewers ...

Page 24: ...er Lock With Internal Tooth 8 45 9201145 Nut Hex 8 32 S S 47 1031320 Spray Head Brewer 48 9202120 Nut Hex 1 8 27 x 1 16 Thick 49 9907223 Gasket S S 13 32 ID x 11 16 OD x 032 Thick 50 6000792 Fitting 1 8 Straight Pipe x 5 16 Hose 52 9903549 Clamp Hose Double Tang 1 2 Diam 53 9903550 Clamp Hose Double Tang 11 16 Diam 54 1031268 Tube Silicone Siphon 3 5 8 Long 55 1034160 Tube Silicone Overflow 8 Long...

Reviews: