7.2
Cleaning
Clean the nozzle
Clean the nozzle after each change of mate-
rial.
Personnel:
Operator
+ additional qualification explosion pro-
tection
Protective equipment:
Use ear protection
Face protection
Respirator mask
Protective workwear
Protective gloves
1. Remove nozzle
2. Blow compressed air through the air
valve from the front.
3. Clean the nozzle in the cleaning bath.
Clean filter.
Clean the filter thoroughly as required to
avoid encrustation of the deposits.
Encrusted deposits make removal difficult.
Personnel:
Operator
+ additional qualification explosion pro-
tection
Protective equipment:
Use ear protection
Face protection
Respirator mask
Protective workwear
Protective gloves
1. Remove filter
2. Clean the filter with a brush.
Do not use a wire brush.
If up to 20% of the filter is still
clogged after cleaning, replace the
filter
4. Remove nozzle
5. Purge the spray gun quickly without the
nozzle
8
Maintenance
8.1
Safety notes
WARNING!
Unsuitable replacement parts in explo-
sive areas
Replacement parts not compliant with the
specifications of the ATEX guidelines can
cause explosions in an explosive atmos-
phere. Serious injury and death could be
the consequence.
– Use exclusively original replacement
parts.
Maintenance
02/2020
EcoGun 2100 - MSG00004EN
20/52