Setting the spray pattern
Fig. 10: Ideal spray pattern
Personnel:
Operator
+ additional qualification explosion pro-
tection
+ Additional qualification high pressure
Protective equipment:
Protective workwear
Respiratory protection device
Face protection
Use ear protection
Safety boots
Protective gloves
1. Close the spraying air supply completely.
If spraying air is blocked, atomi-
zation is done exclusively
through material pressure (airless
mode).
2. Adjust material quantity by means of the
nozzle size and material pressure.
Fig. 11: Rectify the offshoot
3. Open spraying air supply, tilt flat jet con-
trol to the left, until the spray pattern no
longer has any offshoots.
Fig. 12: Shorten spray pattern
4. Adjust the length of the spray pattern by
opening the circular jet control.
Operation
02/2020
EcoGun 2100 - MSG00004EN