The intervals of some maintenance work depend on the used materials. It can be
adapted to the operating conditions.
Interval
Maintenance work
after each use
after each change of material and
paint
Clean nozzle (4) and filter (45)
weekly / after each disassembly
Check grounding of connections and lines.
every 3 months / after every
removal / after every thorough
cleaning with solvent
Lubricate O-ring on the air regulation (13).
Lubricate bearing of the trigger (29).
Lubricate bearing of the retainer lever (22).
Lubrication
NOTICE!
Painting defects due to lubricant con-
taining silicone
If residues containing silicone reach into
the material channels and air channels of
the spray gun, it can produce imperfect
painting results.
– Only use silicone-free oil or grease.
8.3
Dismantle and assemble
8.3.1 Remove the filter.
Remove small filter
Personnel:
Operator
+ additional qualification explosion pro-
tection
+ Additional qualification high pressure
Protective equipment:
Face protection
Protective workwear
Protective gloves
Fig. 15: Remove small filter
Maintenance
02/2020
EcoGun 2100 - MSG00004EN
22/52