OP000509
4-29
Inspection, Maintenance and Adjustment
Check the Operation of All Exterior
Lights, Horn and Control Console
Indicator and Monitor Lights
1.
Turn engine starter switch to "I" (ON) position and
observe all indicator lights.
2.
Restore operation of any light bulbs that do not turn
"ON" at this time.
3.
Sound the horn. Repair or replace if required.
4.
Turn "ON" and inspect all exterior work lights. Replace
any monitors, burned out bulbs or cracked or broken
housings or lenses.
Start Engine, Check Starting Ability, and
Observe Exhaust Color at Start-up
and at Normal Operating
Temperature. Listen for Any
Abnormal Sounds
Check Operation of All Controls
1.
With engine at rated speed, operate all of the controls.
2.
Follow cold weather hydraulic system warm-up
procedures.
3.
Note any slow operations or unusual movements.
Determine the cause and repair fault before operating.
IMPORTANT
Cold weather operation requires that the operator fully
warm up the hydraulic oil before beginning machine
operation. Follow all warm up instructions listed in the
Operating Instruction section of this manual. Make sure
to cycle oil through all of the components, including all
cylinders, both travel motors and the swing motor. Cold
hydraulic oil in the lines and components needs to be
warmed before beginning full operation. If this is not
done, damage to the cylinders or hydraulic motors can
occur.
Summary of Contents for DL200
Page 2: ......
Page 6: ...K1024537E Table of Contents IV ...
Page 7: ...K1024537E I I Presentation 1Presentation PRESENTATION FG008047 Figure 1 ...
Page 17: ...OP000506 1 5 Safety 1 3 10 12 6 4 11 5 9 8 3 7 10 9 4 6 2 FG008049 Figure 1 ...
Page 60: ...OP000506 Safety 1 48 ...
Page 112: ...OP000507 Operating Controls 2 52 CD Player Optional AST DIR FG000109 Figure 101 ...
Page 122: ...OP000507 Operating Controls 2 62 ...
Page 232: ...OP000509 Inspection Maintenance and Adjustment 4 88 ...
Page 242: ...OP000040 Troubleshooting 6 8 ...
Page 252: ...OP000510 Specification 7 10 ...