OP000509
Inspection, Maintenance and Adjustment
4-82
Checking the Relief Pressure of Fan
Motor
Maximum Fan Speed, Checking
1.
Open the radiator grille in order to connect the
pressure gauge.
2.
Connect the pressure gauge to the pressure port (6)
on the inlet hose (3). Check the maximum pressure by
fully depressing the accelerator pedal and reading the
pressure gauge. Maximum fan motor pressure: 100 ±2
kg/cm
2
(The fan speed is approximately 1200 rpm at
this time)
6
3
4
5
2
1
8
7
FG008112
Figure 121
Reference
Number
Description
1
Fan Motor
2
Fan Guard
3
Inlet Line
4
Drain Line
5
Outlet Line
6
Relief Valve
7
Proportional Relief Valve
8
Reversable Solenoid Valve
Reference
Number
Description
Summary of Contents for DL200
Page 2: ......
Page 6: ...K1024537E Table of Contents IV ...
Page 7: ...K1024537E I I Presentation 1Presentation PRESENTATION FG008047 Figure 1 ...
Page 17: ...OP000506 1 5 Safety 1 3 10 12 6 4 11 5 9 8 3 7 10 9 4 6 2 FG008049 Figure 1 ...
Page 60: ...OP000506 Safety 1 48 ...
Page 112: ...OP000507 Operating Controls 2 52 CD Player Optional AST DIR FG000109 Figure 101 ...
Page 122: ...OP000507 Operating Controls 2 62 ...
Page 232: ...OP000509 Inspection Maintenance and Adjustment 4 88 ...
Page 242: ...OP000040 Troubleshooting 6 8 ...
Page 252: ...OP000510 Specification 7 10 ...