Specification
WORKING CAPACITIES
Bucket Capacity
Standard toothed bucket has a capacity of 1.9 m
3
(2.5 yd
3
).
Tipping Load
Static Tipping Load with bucket in Over Front position is
8,870 kg (19,555 lb). With bucket in Fully Turned position,
Static Tipping Load is 7,560 kg (16,667 lb).
Material Weight
The data below describes weight of a cubic meter (cubic
yard) of many types of workload materials.
APPROXIMATE WEIGHT OF
WORKLOAD MATERIALS
MATERIAL
LOW WEIGHT OR
DENSITY
1,100 KG/M
3
(1,850 LB/YD
3
), OR
LESS
MEDIUM WEIGHT OR
DENSITY
1,600 KG/M
3
(2,700 LB/YD
3
), OR
LESS
HIGH WEIGHT OR
DENSITY
2,000 KG/M
3
(3,370 LB/YD
3
), OR
LESS
Charcoal
401 kg/m
3
(695 lb/yd
3
)
---------------------
---------------------
Coke, blast furnace
size
433 kg/m
3
(729 lb/yd
3
)
---------------------
---------------------
Coke, foundry size
449 kg/m
3
(756 lb/yd
3
)
---------------------
---------------------
Coal, bituminous slack,
piled
801 kg/m
3
(1,350 lb/yd
3
)
---------------------
---------------------
Coal, bituminous r. of
m., piled
881 kg/m
3
(1,485 lb/yd
3
)
---------------------
---------------------
Coal, anthracite
897 kg/m
3
(1,512 lb/yd
3
)
---------------------
---------------------
Clay, DRY, in broken
lumps
1,009 kg/m
3
(1,701 lb/yd
3
)
---------------------
---------------------
Summary of Contents for DL200
Page 2: ......
Page 6: ...K1024537E Table of Contents IV ...
Page 7: ...K1024537E I I Presentation 1Presentation PRESENTATION FG008047 Figure 1 ...
Page 17: ...OP000506 1 5 Safety 1 3 10 12 6 4 11 5 9 8 3 7 10 9 4 6 2 FG008049 Figure 1 ...
Page 60: ...OP000506 Safety 1 48 ...
Page 112: ...OP000507 Operating Controls 2 52 CD Player Optional AST DIR FG000109 Figure 101 ...
Page 122: ...OP000507 Operating Controls 2 62 ...
Page 232: ...OP000509 Inspection Maintenance and Adjustment 4 88 ...
Page 242: ...OP000040 Troubleshooting 6 8 ...
Page 252: ...OP000510 Specification 7 10 ...