22
4445103694
Selecting the function for the TR terminal
I
➤
Slide the DIP switches (fig.
position shown in the table below to set the
function for TR terminal.
NOTE
• To activate a change of the settings,
disconnect the device temporarily
from the power supply, the starting
battery and the house battery.
•
E6 vehicles:
Operating with control
signal is required. Operating without
control signal is not available.
DIP switch position
(gray)
Con-
nection
variant
Increase of
charging power
Reduction of
charging power
TR output function
A
• Operation with
control signal:
>10.5 V
• Operation without
control signal:
>13.2 V
• Operation with
control signal:
< 10.2 V
• Operation without
control signal:
< 13.0 V
–
B
• Operation with
control signal:
>10.5 V
• Operation without
control signal:
>13.2 V
• Operation with
control signal:
< 10.2 V
• Operation without
control signal:
< 13.0 V
Control of a normally open
relay (NO):
• Current < 25 A: Battery
control booster active, TR
inactive (NO relay open,
normal operation).
• Current >25 A: Battery
control booster inactive,
TR active (NO relay closed)
C
• Operation with
control signal:
>10.5 V
• Operation without
control signal: –
• Operation with
control signal:
<10.2 V
• Operation without
control signal: –
Control of a normally closed
relay (NC):
• Current < 25 A: Battery
control booster active, TR
active (NC relay open).
• Current >25 A: Battery
control booster inactive,
TR inactive (NC relay
closed, normal operation)
D+
Gel
LiFePO4
AGM 2
Pulser
V
Lead Acid/
AGM 1
Off
D+
Gel
LiFePO4
AGM 2
Pulser
V
Lead Acid/
AGM 1
Off
D+
Gel
LiFePO4
AGM 2
Pulser
V
Lead Acid/
AGM 1
Off
Summary of Contents for BUTTNER MT BCB25/20
Page 3: ...4445103694 3 6 7 1 2 3 5 4 8 1 5 4 3 2 1 8 7 6 2...
Page 4: ...4 4445103694 2 1 3 100 mm 100 mm 4 5...
Page 6: ...6 4445103694 1 2 3 90 a 2 3 5 m 5 m 1 4 5 5 m b...
Page 10: ...10 4445103694 223 270 74 f...
Page 27: ...4445103694 27 Weight 2 85 kg Inspection certification...
Page 150: ......
Page 151: ......