培训手册
Training Manual
传感器设定及称重标定
Sensor Setting and Load Calibration
JCPT-HD/DC
www.cndingli.com
6-3
老款水平传感器设定(
Old Tilt Sensor Set State
)
1)
将机器行驶到坚硬的水平的地面上。(
Drive machine to the level and hard ground.
)
2)
找到传感器的侧面的清零按钮
“SET ZERO”
,按住按钮,直到传感器上的这个指示灯红绿交替
闪烁(
Find there set button“SET ZERO”on the side of the sensor, press the button, the
indicator light on the sensor until the alternating red and green flashes.
)
3)
连续再按三下传感器上的清零按钮后,指示灯闪烁停止,传感器上绿灯常亮,传感器清零工作
完成。(
Continuous press three times with reset button, lights flashing, the green light on,
the sensor set zero is finished.
)
1.2
角度传感器设定(
Angle Sensor Set State
)
1)
打开机器所有电源。(
Open the machine power.
)
2)
起升机器选择合适的高度清零,参见如下步骤。确保机器最低位与最高位的角度传感器输出电
压(白色线与黑色线)在
1.0V-4.0V
之间。(
lift the machine chooses the suitable height to
set zero, see the following steps. Ensure that the lowest and highest angle sensor output
voltage (white wire and black wire) is between 1.0V-4.0 V.
)
3)
找到传感器的正面的清零按钮
“SET ZERO”
,按住按钮,直到传感器上的这个指示灯红绿交替
闪烁。(
Find the reset button“SET ZERO”on the side of the sensor,press the button, the
indicator light on the sensor until the alternating red and green flashes.
)