The green light in the control centre on the platform is lit, when the platform is within the
allowed operating range.
The reach are limit switch
RK4
stops the movements that impair the stability of the lift
(extending the telescope and lowering the boom) at a predetermined position.
Adjusted values of the limits:
100 mm
w
W
RK4 - L RK5 - L
160XT/XTB II
270 kg 1925 mm 2175 mm +0 / -50 mm
180XT/XTB II
215 kg 2300 mm 2570 mm +0 / -50 mm
210XT/XTB II
80 kg 3025 mm 3525 mm +0 / -50 mm
The red warning light for overloading will illuminate as soon as the
RK4
has stopped the
movement. While at the outreach limit, the red warning light and the green signal light will
flash in turns. In this situation, the lift can be operated in the direction, in which it remains
inside the permitted outreach area.
The overload limit switch
RK5
backs up, if the
RK4
, for some reason, does not work.
Once the RK5 is activated, the red warning light for overloading in both control centres will
be continually illuminated, and a warning buzzer will sound on the platform.
The operation of the overload limit switches is based on monitoring of the boom's lifting
torque.
PRESSURE SPRING
LIFTING CYLINDER
ARTICULATED ARM
LIMIT SWITCHES RK4, RK5
ADJUSTMENT
SCREWS
DANGER
WARNING
CAUTION
NOTICE
The limit switches must never be readjusted, nor the operation of the mechanism be
impeded.
Risk of turning over the lift!
Summary of Contents for DINO 210XTB II
Page 2: ......
Page 9: ...9 2 1 DIMENSION DRAWINGS 2 1 1 160 XTB II...
Page 10: ...10 Operating instructions DINO 160XTB 180XTB 210XTB 2 1 2 180 XTB II...
Page 11: ...11 2 1 3 210 XTB II...
Page 52: ...52 Operating instructions DINO 160XTB 180XTB 210XTB NOTES...
Page 53: ...53 NOTES...
Page 57: ...57 7 2 LUBRICATION PLAN 6 9 7 11 7 8 1 5 5 3 2 12 3 4 10 13...
Page 61: ...61 BLANK...
Page 64: ...64 Operating instructions DINO 160XTB 180XTB 210XTB BLANK...
Page 66: ...66 Operating instructions DINO 160XTB 180XTB 210XTB NOTES...
Page 67: ...67 NOTES...