3
(see section [377]), Opt [1] alarms, [2] tampers, [3] trou-
bles.
• Programmable keypad lockout option (see section [012])
• Automatic arming by partition at a specified time, each
day of the week
• No activity arming
• Keypad activated alarm output and communicator test
• Keypad lockout
• Audio capability using the PC5900 Audio Verification
Module and central station 2-way listen-in
• All modules connect to the system via a 4-wire Keybus,
up to 1000’/305m from the main panel
• Event buffer can be printed using PC5400/PC5401 RS-
232 Serial Interface module
• Supports the Escort5580(TC) Voice Prompt Module,
with automation and lighting control
• 500 event buffer, time and date stamped
• Uploading/downloading capability
• Daylight savings time option
1.4 Additional Devices
If a Fault or Tamper condition occurs on a zone while the
system is disarmed, a trouble condition will be indicated. If a
Fault or Tamper condition occurs on a zone while the system
is armed, the bell will be sounded. This applies to zones and
zone expander modules, and cannot be changed. This fea-
ture will be active for the following modules:
• PC5108
• PC5700
• PC5132
• PK55XX with a zone programmed
• RFK55XX with a zone programmed
Keypads
A maximum of 8 keypads can be connected to the control
panel. You can connect any combination of the following
listed.
• PK5500/RFK5500 LCD keypad
• PK5501/RFK5501 ICON keypad
• PK5508/RFK5508 8 Zone LED keypad
• PK5516/RFK5516 16 Zone LED keypad
• LCD5511 Fixed Message LCD keypad
• LED5511Z 8 Zone LED keypad
• PC5508Z 8 Zone LED keypad
• PC5532Z 32 Zone LED keypad
• PC5516Z 16 Zone LED keypad
• LCD5500Z Liquid Crystal Display (LCD) keypad
• LCD5501Z LCD-style keypad
PC5100 2-Wire Addressable Interface Module
The PC5100 module is used to connect 2-wire addressable
devices to the system. Up to 32 2-wire addressable devices
can be added to the system.
NOTE:
PC5100 v1.0 and lower modules can only support the
first 32 zones on the PC1616/PC1832/PC1864 system.
NOTE:
PC1616 expandable to 16 zones only.
PC5108 Eight Zone Expander Module
Eight zone expander module can be used to increase the
number of zones on the system. Up to 7 modules can be
connected to increase the system zones to a maximum of 64
(see the PC5108 Installation Instruction Sheet.)
NOTE:
PC5108 v1.0 and lower modules can only support the
first 32 zones on the PC1616/PC1832/PC1864 system. PC5108
v1.0 and lower modules enroll as two modules and use up
two supervisory slots.
NOTE:
Do not mix PC5108 v1.x and lower modules with
PC5108 v2.0 and higher modules on the same system.
NOTE:
PC1616 expandable to 16 zones only. The PC1832
expandable to 32 zones only.
PC5132 Wireless Receiver Module
The PC5132 Wireless Receiver module can be used to con-
nect up to 32 fully supervised wireless devices (see the
PC5132 Installation Manual for details).
NOTE:
Only the first 32 zones on the PC1616/PC1832/PC1864
system can be used as wireless zones.
NOTE:
PC1616 expandable to 16 zones only.
PC5200 Power Supply Output Module
The PC5200 can provide up to 1 Amp of additional power for
modules or devices connected to the control panel. Up to 4
modules can be connected to the system. Each module
requires a 16.5V
AC
40VA transformer and 4 AH battery (see
PC5200 Installation Instructions for details).
PC5204 Power Supply Output Module
The PC5204 can provide up to 1 Amp of additional power for
modules or devices connected to the control panel. The
module requires a 16.5V
AC
40VA transformer and 4Ah(min.)
battery. In addition, the module provides 4 programmable
high current outputs (see PC5204 Installation Instructions for
details).
PC5208 Eight Low Current Output Module
Adds 8 programmable low current outputs (50mA) to the
control (see the PC5208 Installation Instructions for details).
NOTE:
If you use the main panel and the PC5208 outputs,
PGM 3 will work the same as the first PC5208 output, and
PGM 4 will work the same as the second PC5208 output.
Escort5580(TC) Module
This Escort5580(TC) module will turn any touch-tone tele-
phone into a fully functional keypad. The module also
includes a built-in interface to control up to 32 powerline car-
rier type devices for lighting and temperature control (see the
Escort5580(TC) Installation Manual for details).
NOTE:
An Escort5580(TC) version 3.x or higher is needed to
support more than 32 zones and/or 2 partitions.
PC5900 Audio Verification Module
The PC5900 series Audio Verification Modules provide "Talk/
Listen-In" capability for audio verification of alarms. The
module permits the central station to monitor up to four
microphones and to communicate to the occupants through
2 separate speakers.
PC5400 Printer Module
This PC5400 Printer Module allows the panel to print all
events on the system to any serial printer. All events will be
printed with the partition, time, date and the event that
occurred (see PC5400 Installation Manual for details).
NOTE:
The PC5400 v2.x and lower only supports events on
partitions 1 and 2, and zones 1-32.
PC5401 Serial Interface Module
The PC5401 Serial Interface Module can be used to commu-
nicate with 3’rd party devices (automation) through a stan-
dard RS-232 serial connection (see the PC5401 Developer’s
Guide for more information on communicating with the
PC5401 module).
T-Link Local Area Network Communicator
The T-Link Local Area Network Communicator provides an
efficient method of communicating via a Local Area Network
(LAN). See the T-Link Installation Manual for more details.
TL250/TL300 Intranet/Internet Communicators
The T-Link Ethernet Communicator provides an efficient
method of communicating via Internet/Intranet. See the T-
Link TL250/TL300- Installation Manual for more details.
Alternate Communicators
Refer to the associated Skyroute™ Installation Manual, or
GS3050 Installation Manual for programming details.