46
NOTE:
To perform DLS via the T-Link module, Option [1], Section 401 must be enable or the number of rings in section 406 must be
programmed.
NOTE:
Option [2] applies to DLS via T-Link as well.
NOTE:
Option [3] and [4] cannot be performed through T-Link.
[402] - Downloading Computer’s Phone Number
This telephone number is 32 digits in length.
[403] - Downloading Access Code
This 6-digit hexadecimal code allows the panel to confirm that it is communicating with a valid downloading computer.
[404] - Panel Identification Code
This 6-digit Hexadecimal code allows the downloading computer to confirm the identity of the control panel.
[405] - Double-Call Timer
This timer sets the amount of time that can be taken between calls when using Double Call to contact the panel. Valid entries are
001 to 255 (seconds).
[406] - Number of Rings to Answer On
The value in this section determines how many rings that the panel will automatically pick up on in order to establish a DLS connec-
tion. Default value is 000 rings. Valid entries are [000]-[020].
NOTE:
If Section [401] Option 1 and Section [406] are enabled, either one will work depending on how the installer calls the premises.
[499] - Initiate PC-Link Communications
The installer may initiate a PC-Link DLS session between a computer and panel by entering this section in the following manner:
[499] - [Installer’s Code] [499].
The installer should already have the PC-Link Cable properly connected between the panel’s header and the downloading com-
puter as well as have the DLS file waiting for the panel to connect before entering this command.
NOTE:
PC-Link cannot be initiated while the panel is communicating via the phone line.
5.7 Programmable Output Programming
[501]-[514] - Programmable Output Attributes
PGM output attributes and output type must be programmed for each PGM output. PGM output options [09] “System Trouble” and
[10] “Latched System Event” have a unique set of attributes listed below the description of each output type.
PGM attributes return to their default settings when PGM output options are changed. See the programming worksheets for the PGM
output types defaults.
CAUTION: Select the normal and active states of each PGM output to ensure that undesirable output states do not occur
after a loss and restore of AC power.
If you program more than one PGM output as the same output type (e.g. If PGM 1 and PGM 2 are both programmed as [19] Com-
mand Output 1), the settings for output attributes [1], [2] and [5] must be the same. This does not apply to outputs programmed as
types [09] and [10].
NOTE:
Attribute [3] must be ON for PGM Option [16].
Assigning Partitions to Programmable Outputs
By default, all programmable outputs are assigned to partition 1. For programmable outputs to work on other partitions, enable or dis-
able the appropriate partitions in the Partition Assignment programming sections.
PGM Output Partition Assignment . . . . . . . . . Sections [551] - [564]
PGM Output timer. . . . . . . . . . . . . . . . . . . . . . . . . . . Section [170[
5
Auto Event Buffer Upload
ON
Auto Event Buffer Upload Enabled
. After the panel has communicated the "Event Buffer 75%
Full" event to central station, the panel will call the Downloading Computer's telephone number.
DLS software will then perform an event buffer upload upon successful connection.
OFF
Auto Event Buffer Upload Disabled
. After the panel has communicated the "Event Buffer 75%
Full" event to central station, the panel will not call the Downloading Computer's telephone num-
ber.
6
For Future Use
7
For Future Use
8
For Future Use
PGM Output Types [01], [03], [04], [05]-[08], and [17]-[18]
1
Future Use
NOTE: This option must be off to ensure proper PGM operation.
2
Future Use
NOTE: This option must be off to ensure proper PGM operation.
3
Output Level
ON
True Output
The output will activate (switch to Ground) when the event occurs.
OFF
I
nverted Output
The output will de-activate (switch to open) when the event occurs.
PGM Output Types [03], and [19]-[22]
4
Output Options
ON
Output Pulsed
The output will activate for the duration programmed in for the PGM Output Timer
in Section [164]. This default period is 5 seconds.
OFF
Output On/Off
The output will toggle between on and off when the corresponding [*][7] command
is entered.
PGM Output Types [19]-[22]
5
Access Code Options
ON
Code Required
Access Code Required for Activation.
OFF
No Code Required
No Access Code Required for Activation.
Option
Downloading Code
On/Off
Description