32
[022] - Ninth System Option Codes
[023] - Tenth System Option Codes
Option
Definition
On/Off
Description
1
Access Code
Required for [*][1],
[*][2], [*][3]
ON
Access code is required for [*][1], [*][2] and [*][3] menu options
In order to access the [*][1] bypass
menu, [*][2] trouble menu, or [*][3] alarm memory menu a valid access code is required. Events will also be
generated and logged, thus identifying the user.
NOTE: You must have a version LCD5500 3.40U or greater keypad, PK55XX or RFK55XX Keypad.
NOTE: This feature is not supported by the PC5400.
OFF
No access code required for [*][1], [*][2], [*][3] menu options
No access code is required In order to
access the [*][1] bypass menu, [*][2] trouble menu, or [*][3] alarm memory menu.
2
Keypad Blanking
while Armed
ON
Keypad Blanking while Armed
Keypad will blank after the programmed time (Section [021], Option 3)
when the system is armed.
NOTE: This feature will only blank after exit delay has expired.
OFF
Keypad follow regular blanking option
Keypad will blank after the programmed time (Section [021],
Option 3) when the system is armed or disarmed.
3
Auto-Arming/Force
Arming Open Zones
ON
Auto-Arming/Force Arming Open Zones
All zones will be force armed during an autoarm regardless of
the force arm attribute on the zone.
OFF
Auto Arming follows Force Arming Attribute
Only zones with the force arm attribute enabled will be
force armed during an autoarm.
4
Master Code
Bypasses Holdup
ON
Master code bypasses holdup zones only
Attempting to bypass a hold-up zone with any other access
code will generate error tone.
OFF
Any code can bypass hold up zones
Any code can bypass Hold up zones
5
Time Limit for PGM
05, 06, 17, 18
ON
Time Limit Enabled for PGM 05, 06, 17, 18
Setting Keypad Blanking Option ON - Option 5 Programming
Section [022] - may satisfy this requirement. The panel will turn off all lights and LCDs on the keypads if no
key is pressed for 30 or for 5 seconds – depending on the status of toggle option 3 in Programming Section
[021] irrespectively of the armed or disarmed state of the Intruder alarm system. Implementation of the
option 3 in Programming Section [021] shall allow the installer to enable/disable the 5 seconds time limit
for Programmable Output Options 05 (Armed Status), 06 (Ready to Arm), 17 (Away Armed Status) and 18
(Stay Armed Status).
OFF
Time Limit Disabled for PGM 05, 06, 17, 18
Listed PGM’s will not turn off (time out)
6
RF Delinquency
Enable
ON
RF Delinquency Enabled
If any wireless zone supervisory transmission is not received by the PC5132 dur-
ing a 15-minute period, the PC5132 will place the panel into Not Ready To Arm mode. In the armed state,
the Zone faults will generate tamper alarms. The panel will generate a silent trouble (NO trouble beeps but
the Trouble LED is turned ON) called “RF Device Delinquency”, that’s only viewable in [*][2] (Trouble Mem-
ory). The user can override the condition and arm the panel by using the feature.
OFF
RF Delinquency Disabled
The system will not indicate an RF Delinquency when a zone supervisory trans-
mission is not received during a 15 minute period.
7
Open Zones Cancel
Arming
ON
Open Zones Cancel Arming
If there is an open zone at the end of exit delay, arming of the system will be
canceled.
OFF
Open Zones Cancel Arming Disabled
If there is an open zone at the end of exit delay the system will
arm with the zone open.
8
Audible Exit Delay
for Stay Arming
ON
Audible Exit Delay for Stay Arming
When the system is armed in Stay mode the exit delay will be
sounded by 1 beep every 3 seconds.
OFF
Stay Arming is Silent
When the system is armed in Stay mode the exit delay will be silent.
EN
EN
EN
EN
EN
Option
Definition
On/Off
Description
1
[F] Key Beeps
ON
[F] Key Beeps Only
Whenever the [F] is pressed you will only get the acknowledge beeps from the key-
pad. The bell will not sound.
OFF
[F] Key Beeps and Sounds Bell
[F] key will beep the keypad and trigger the bell output
2
200 Baud Open/
Close Identifier
Toggle ON/OFF
ON
200 Baud Open/Close Identifier Toggle ON
200 Baud Open Close Identifier is 2 for arming 1 for disarm-
ing
OFF
200 Baud Open/Close Identifier Toggle OFF
200 Baud Open Close Identifier is 1 for arming 2 for dis-
arming
3
Test Transmission
While Armed Only
ON
Test Transmission While Armed Only
The Panel will send a test transmission at the programmed interval
and time if the system is armed.
OFF
Test Transmission While Armed or Disarmed
The Panel will always send a test transmission at the pro-
grammed interval and time.
4
Transmission
Counter
ON
Transmission Counter in Hours
The Panel will send a test transmission after the programmed number of
hours in the test transmission cycle (Section [377], Option 7)
OFF
Transmission Counter in Days
The Panel will send a test transmission after the number of days pro-
grammed in the test transmission cycle (Section [377], Option 7) at the programmed time.
5
Stay/Away Toggle
Option
ON
Switching from Away to Stay Disabled
The system can not be switched from Away to Stay mode by
pressing the [Stay] function key.
OFF
Away to Stay Toggle Option Permitted
The system can be switched from Away to Stay mode by press-
ing the [Stay] Function key.
6
2-way Audio Discon-
nect
ON
2-way Audio Will Not Disconnect For New Event
The system will not disconnect the 2-way audio ses-
sion if a new event occurs on the system.
OFF
2-way Audio Will Disconnect For a New Event
The system will disconnect the 2-way audio session if a
new event occurs on the system.