59
B.2 PC1616/PC1832/PC1864 Standard Wiring Diagram
PC Board
Cabinet
Stand Off
Primary:120VAC/60Hz.
Secondary: 16.5VDC 40VA
DSCPTD 1640U
Class II Transformer
NOTE: Do not connect
transformer to receptacle
controlled by a switch
Incorrect connections may result in PTC failure or improper operation.
Inspect wiring and ensure connections are correct before applying power.
WARNING:
Incorrect connection of batteries may result in battery rupture or Fire Hazard.
Do NOT allow metal objects to connect the Positive and Negative Terminals.
Ensure that batteries are connected with correct polarity (Red to (+), Black to (-)).
Failure to comply with this may result in battery rupture and/or Fire Hazard.
All circuits are classified for UL Installations as Power Limited/Class II Power Limited
except for battery leads which are not power limited.
Do NOT route any wiring over circuit boards. Maintain at least 1"(25.4mm) separation.
A minimum of 1/4" (6.4mm) separation must be maintained at all points between
power limited wiring and all other non-power limited wiring.
1. Insert Stand off into cabinet
mounting hole in the
desired location. Snap-in-
place.
2. Position circuit board
mounting holes over
standoffs. Press firmly
on board to snap-in-place.
IMPORTANT:
a)This equipment, Alarm Controller PC1616/1832/1864 shall
be installed and used within an environment that provides the
pollution degree max 2 and overvoltages category II
NON-HAZARDOUS LOCATIONS, indoor only. The equipment is
FIXED and PERMANENTLY connected and is designed to be
installed by service persons only; [service person is defined as a
person having the appropriate technical training and experience
necessary to be aware of hazards to which that person may be
exposed in performing a task and of measures to minimize the risks
to that person or other persons.]
b)The connection to the mains supply must be made as per the local
authorities rules and regulations.
An appropriate disconnect device must be provided as part of the
building installation. Where it is not possible to rely on identification of
the neutral in the AC Mains supply the disconnecting device must
disconnect both poles simultaneously (line and neutral). The device
shall disconnect the supply during servicing.
c)The equipment enclosure must be secured to the building structure
before operation.
e)Internal wiring must be routed in a manner that prevents:
- Excessive strain on wire and on terminal connections;
- Loosening of terminal; connections;
- Damage of conductor insulation
f) Disposal of the used batteries shall be made according to the waste
recovery and recycling regulations applicable to the intended market.
g) Before servicing, DISCONNECT the telephone connection.
See corresponding Section NumberText for wiring details.
CON1
BAT+BAT-
FUSE
AC AC
16.5V
/40VA
AC
To EGND
Terminal
230 V
/50 Hz International
AC
CON1
BAT+BAT-
POWER LIMITED
NON-POWER LIMITED
DSC Model BD7-12
or equivalent
Battery
StandbyTime:
24Hrs min.
BLACK
RED
TB-2
AC AC
RED BLK YEL GRN
Z1 COM Z2 Z3 COM Z4 Z5 COM Z6 Z7 COM Z8
AUX+
BELL+
AUX-
BELL-
PGM1 PGM3
EGND
TIP
T-1
PGM2 PGM4
RING R-1
DSC
220220
UA503
Cable Tie (not supplied) recommended
PC1864
Only
PC1864
PC1832
Only
PC1616/1832/1864
See Section 9
for ground wiring details
High Voltage. Disconnect AC Power
and telephone lines before servicing
WARNING:
High Voltage. Disconnect AC Power
and telephone lines before servicing
WARNING:
9
8
4
3
1
5
6
2
7
TB-2
AC AC
RED BLK YEL GRN
Z1 COM Z2 Z3 COM Z4 Z5 COM Z6 Z7 COM Z8
AUX+
BELL+
AUX-
BELL-
PGM1 PGM3
EGND
TIP
T-1
PGM2 PGM4
RING R-1
DSC
REV XX
220220
UA503
CON1
BAT+BAT-
PC-LINK
Internally Connected
AUX+ and Keybus (Red) are Internally Connected
Total current draw from Keypads, PGM Outputs and
Aux circuits must not exceed 550ma
PC1864
Only
PC1864
PC1832
Only
PC1616/1832/1864
10
12V / 7 AHr
12V / 7 AHr
North America Only