8
NOTE:
All keypad assignments must be done at each keypad
on the system. When using LCD keypads, one keypad must
remain in slot 8 to upload/download LCD information. Do
not assign more than one keypad to the same slot.
NOTE:
The following keypad versions can only be used on
the Partition 1 & Partition 2, and the first 8, 16, or 32 zones:
PC5508(Z), PC5516(Z), PC5532(Z) versions v2.0 & lower,
LCD5500(Z) versions 3.x and lower. To assign a keypad to a
slot and select the partition it will operate in, enter the fol-
lowing:
Function Key Programming
Each of the 5 function keys on each keypad may be pro-
grammed for different operations.
1. Enter Installer Programming.
2. Press [000] for Keypad Programming.
3. Enter [1] to [5] to select function key to program.
4. Enter a 2-digit number for function key option - [00] - [32].
5. Continue from step 3 until all function keys are pro-
grammed.
6. Press [#] key twice to exit Installer Programming.
For details on the operation of Function Keys, see section
4.3 ’Function Keys’ .
2.8 Confirming Module Supervision
By default, all modules are supervised upon installation.
Supervision is enabled at all times so that the panel can indi-
cate a trouble if a module is removed from the system.
To check which modules are currently connected and super-
vised:
1. Press [*][8][Installer Code] to enter Installer Program-
ming.
2. Press [903] to display Module Supervision Field.
3. On an LCD keypad, use the arrow keys to scroll through
the modules the panel has found on the system.
On LED/ICON keypads, zone lights will be turned on
according to what modules the panel has found on the
system. Refer to the following chart:
If a module is connected but does not show as being
present, it may be due to any of the following reasons:
• it is not connected to the Keybus
• there is a Keybus wiring problem
• the module is more than 1,000'/305m from the panel
• the module does not have enough power
• the wireless receiver does not have any devices added
NOTE:
Module supervision will not display correctly at an
LCD5500Z v2.x and lower keypad.
2.9 Removing Modules
If a module is no longer required on the system, the panel
must be told to stop supervising the module. To do this:
1. Power down the panel by removing the backup battery
and AC.
2. Remove the module from the Keybus.
3. Power up the panel by connecting the backup battery
and AC.
4. Press [*][8][Installer Code] to enter Installer Program-
ming.
5. Press [902] to enable supervision. The panel will auto-
matically search for all modules connected to the system
for the next 60 seconds. Do not perform any other oper-
ations during this 60 second period.
6. Once the search is complete enter section [903] to con-
firm that the correct modules are supervised on the sys-
tem.
2.10 Zone Wiring
For a complete description of the operation of all zone types,
see section 5.2 ’Basic Programming’ section [001]-[004].
The panel can be programmed to supervise normally closed,
End of Line, or Double End of Line loops. Refer to the follow-
ing sections to study each type of individually supervised
zone wiring.
NOTE:
Any zone programmed for Fire or 24 Hour Supervi-
sory must be wired with a single End of Line (EOL) resistor
regardless of the type of zone wiring supervision selected for
the panel (section [013], options [1] and [2]). See Zone Defini-
tions [001]-[004]. If you change the zone supervision options
from DEOL to EOL or from NC to DEOL (section [013], options
[1] or [2]), power the system down completely, and then
power it back up for correct operation.
NOTE:
For UL Listed Installations use SEOL or DEOL only.
NOTE:
Use minimum 22 AWG wire, maximum 18 AWG wire.
NOTE:
Do not use shielded wire.
NOTE:
Wire run resistance shall not exceed 100
Ω
.
Burglary Zone Wiring Chart
Normally Closed (NC) Loops
To enable normally closed loops, program section [013],
option [1] to ON.
NOTE:
Do not use Normally Closed Loops for UL Listed sys-
tems
.
Keypad Function Keys
[00] - Null
[10] - Alarm Memory
[24] - Bypass Group Recall
[01] - Partition 1 Select
[11] - User Programming
[26] - Time & Date Program
[02] - Partition 2 Select
[12] - User Functions
[27] - Partition 3 Select
[03] - Stay Arm
[13] - Command Output 1
[28] - Partition 4 Select
[04] - Away Arm
[14] - Command Output 2
[29] - Partition 5 Select
[05] - No Entry Arm
[16] - Quick Exit
[30] - Partition 6 Select
[06] - Chime On/Off
[17] - Activate Stay/Away
[31] - Partition 7 Select
[07] - System Test
[19] - Command Output 3
[32] - Partition 8 Select
[08] - Bypass Mode
[21] - Command Output 4
[09] - Trouble Display
[23] - Bypass Recall
Light
Module/Device
Light
Module/Device
[1]
Keypad 1
[16]
Zones 57 to 64
[2]
Keypad 2
[17]
Wireless Receiver
[3]
Keypad 3
[18]
PC5208
[4]
Keypad 4
[19]
PC5204
[5]
Keypad 5
[20]
PC5400
[6]
Keypad 6
[21]
PC5900
[7]
Keypad 7
[22]
Alternate Communicator
[8]
Keypad 8
[23]
Future Use
[9]
Zones 9 to 16
[24]
Escort5580(TC)
[10]
Zones 17 to 24
[25]
Future Use
[11]
Zones 25 to 32
[26]
PC520X-1
[12]
Zones 33 to 40
[27]
PC520X-2
[13]
Zones 41 to 48
[28]
PC520X-3
[14]
Zones 49 to 56
[29]
PC520X-4
[15]
PC5100
Wire Gauge
Maximum Wire length to End of Line Resistor
24
1900 feet / 579 meters
22
3000 feet / 914 meters
20
4900 feet / 1493 meters
19
6200 feet / 1889 meters
18
7800 feet / 2377 meters
ANY Z
TERMINAL
ANY COM
TERMINAL
ANY Z
TERMINAL
ANY COM
TERMINAL