7–20
Chapter 7 – RUN Mode and Errors
GLC2400/2500/2600 Series User Manual
NETWORK ADDRESS
ERROR (02 : F8)
The SIO address used for this GLC
is different from other GLC units.
(Only for the multi-link connection)
Check all GLC unit's SIO address
settings, and correct any that are
incorrect.
PLC COM. ERROR (02:**)
Specific PLC related error, or an
error has occurred with the PLC.
See
7.5 –
"Error Message Details."
SCREEN MEMORY DATA
IS CORRUPT
(nnnn:mmmm)
ScreenData is corrupted:
*nnnn indicates the Screen Number
that has an error.
*mmmm indicates the number of
screens that have errors.(Decimal)
Check the screens that have errors,
correct all errors, and then transfer
the screen data again.
CLOCK SETUP ERROR
The backup battery for the internal
clock is running low.
See
7.5 –
"Error Message Details."
SCREEN TRANSFER
ERROR
An error occurred in the data
transmission from the screen editor
to the GLC panel.
Re-transfer the screen data.
SCREEN TAG LIMIT
EXCEEDED
Tags are setup beyond the tag limit
(max. of 385)
See
7.5 –
"Error Message Details."
OBJ. PLC HAS NOT
BEEN SET UP (**)
The host PLC set up in the Editor
does not match the PLC in use.
See
7.5 –
"Error Message Details."
A CF Card that is not compliant with
the GLC is being used.
Use an optional CF Card.
The CF Card is not recognized due
to the timing of the CF Card Insertion
and Removal.
Either reinsert the CF Card or turn
the GLC OFF and then ON again
while the CF Card is still inserted.
D-SCRIPT ERROR (***)
D-Script settings (data) are
incorrect.
See
7.5 –
"Error Message Details."
GLOBAL D-SCRIPT
ERROR (***)
Global D-script settings (data) are
incorrect.
See
7.5 –
"Error Message Details."
EXTENDED SIO SCRIPT
ERROR (***)
Extend SIO script settings (data) are
incorrect.
See
7.5 –
"Error Message Details."
SERIAL I/F CHANGE
ERROR
The GP currently in use does not
support the "Serial I/F Switch"
feature, however in the GP screen
editor, "Yes" has been specified for
the switch.
See
7.5 –
"Error Message Details."
CF CARD RECOGNITION
ERROR