Chapter 6 – Initializing the GLC
GLC2400/2500/2600 Series User Manual
6–15
You can perform FORCE RESET in either RUN mode or OFFLINE mode.
•
The Menu Bar will not display when the GLC is starting up.
•
Entering SYSTEM RESET is possible even when the PLC
and GLC are not communicating.
Set up the touch panel’s Touch Operation and Force Reset modes, and adjust the
Display Device settings in this screen. Depending on the GLC type, these settings
may vary.
6.4.3 SET UP TOUCH PANEL
TOUCH OPERATION MODE
Designates One Point, Two Points, or No Slide. When No Slide is selected, the
screen will NOT respond to one’s finger dragging across the touch screen. Only
individually-selected points will register.
FORCE RESET MODE
Enables or disables the display of the menu bar (force reset page). When set to
“Yes,” the menu bar will display.
To Display the Menu Bar
To enter the
SYSTEM RESET
mode, press the bottom-right corner of the screen
(position 1, below), and then touch the top-right and bottom-left corners (posi-
tions 2 and 3).
To activate Reset, touch the
RESET
button; to change to
OFFLINE
Mode, touch
OFFLINE
.