General Specifications & Advantages
Wide IEC, ANSI and custom delay curve support,
DMT and IDMT delay curve support for all overcurrent protection functions,
Annunciating functions and 7 optically coupled programmable inputs that eliminate the need to
use external annunciators (e.g. to evaluate Buchholz, temperature and pressure signals).
8 outputs: Trip (SPDT) and watchdog (SPDT) plus 6 programmable outputs (2 SPDT + 4 SPST),
Full screen R – S – T and N ampermeter display, measurement functions that eliminate the need
to use double core CTs, external ampermeter and frequency-meters,
X / 1 A and X / 5 A current transformer compatibility in a single unit,
Wide setting ranges; (0.1-40) I
n
current setting range, (0.01-150) s DMT delay setting range,
(0.025-3.2) IDMT (TMS & RTMS) delay setting range.
2 independent settings groups,
3 independent thresholds for phase overcurrent protection,
3 independent thresholds for earth overcurrent protection,
2 independent thresholds for negative sequence overcurrent protection,
Broken conductor sensing, trip and alarm,
1 threshold phase undercurrent protection,
Thermal overload protection with thermal image according to IEC 60255-8 ed.2.0,
Auto-recloser with 4-shots, auto-reclosing programmability for each protection function,
Cold-load pickup function with high reliability CB-triggering,
Blocking logic selectivity feature,
Delaying logic selectivity feature,
Circuit breaker failure supervision and alarming,
Circuit breaker supervision functions: opening and closing time supervision; charging spring
supervision; numerator, ΣA and ΣA² supervision for each pole; trip circuit supervision,
Automatic secondary shorting,
Quick alarm menu access and enhanced alarm explanations;
8 programmable alarm LEDs,
Event and fault records up to 151 instances,
5 waveform records with 3 seconds duration each,
Electro-magnetic compatibility tested for IEC directives,
Draw-out system that enables under-load unit displacement / replacement,
Largest LCD graphics screen in its class (128 px x 64 px); easy-to-navigate user friendly menus
similar to mobile phones’,
Auxiliary supply voltage compatibility with all voltages in the field;
U
aux
= (24 – 240) V
DC
/ (24 – 240) V
AC
,
IP52 front side and IP20 backside environmental protection,
SCADA ready,
USB and RS485 communication ports; MODBUS RTU, IEC 60870-5-103 and DEMCOM
communication protocols support,
High precision manufacturing,
Free-of-charge PC software and accessories,
Fast and low cost repairs thanks to the modular electronics,
Matchless customer support, a variety of application diagrams and technical documents. □
Summary of Contents for CPM 310 G
Page 1: ...CPM 310 G Digital Overcurrent Protection Relay User Application Manual vEN 2016 03...
Page 2: ...2...
Page 6: ...6 ABOUT DEMA...
Page 11: ...11 INTRODUCTION...
Page 32: ...32 PACKING LABELING INFORMATION...
Page 34: ...34 OPERATING MANUAL...
Page 53: ...53 RELAY MENUS MANUAL...
Page 55: ...55 The Menu Tree...
Page 56: ...56...
Page 57: ...57...
Page 58: ...58...
Page 59: ...59...
Page 60: ...60...
Page 61: ...61...
Page 128: ...128 DIGICONNECT PC PROGRAM MANUAL...
Page 189: ...189 APPLICATION DIAGRAMS...
Page 191: ...191 Sample Power Transformer Protection Application Diagram...
Page 193: ...193 FUNDAMENTAL CABLING DIAGRAM...
Page 203: ...203 APPLICATION DIAGRAM NO 10 RS485 Cabling...
Page 204: ...204 TECHNICAL DATA...
Page 220: ...220 GLOSSARY...