TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0)4194 98811-88
Subject to technical changes.
FAX: 04194 9881-29, E-Mail: [email protected], www.tcsag.de
PI_TOER2-EB_uk2 2A
mi
Product information
Door release relay for
location-independent installation
TOER2-EB
Safety instructions
WARNING!
When working on main power connections of 230 V AC, the general and regional instal-
lation and safety regulations must be met. i.e. DIN VDE 0100
The device is to be installed and commissioned only by qualified electricians!
Important note on commissioning
During the transportation, the relay might have been exposed to severe shocks. As a re-
sult, the contact might move into operating position (K1-K2 closed).
!
At the beginning of the commissioning connect the TCS:BUS to the relay and to the
mains power to move the contact into its rest position.
Device overview
Technical data
supply voltage:
+ 24 V ± 8 %
housing: plastics
dimensions (in mm):
52 x 52 x 23
weight 25
g
Acceptable ambient temperature: -20 °C ... 50 °C
Input current (2-wire):
I(a) = 1.2 mA,
input current (3-wire):
I(a) = 0.4 mA
I(P) = 0.8 mA
I(Pmax) = 6.5 mA
Connecting diameter:
0,4 ... 0.8 mm
recommended length for separation:
5 ... 6 mm
TCS:BUS
connection
terminals
relay con-
nection
terminals
jumper