qos-policy-input 3 layer2
rate-police 30
!
interface TenGigabitEthernet 1/21
no ip address
switchport
vlan-stack access
vlan-stack dot1p-mapping c-tag-dot1p 0-3 sp-tag-dot1p 7
service-policy input in layer2
no shutdown
Mapping C-Tag to S-Tag dot1p Values
To map C-Tag dot1p values to S-Tag dot1p values and mark the frames accordingly, use the following commands.
1.
Allocate CAM space to enable queuing frames according to the C-Tag or the S-Tag.
CONFIGURATION mode
cam-acl l2acl
number
ipv4acl
number
ipv6acl
number
ipv4qos
number
l2qos
number
l2pt
number
ipmacacl
number
ecfmacl
number
{vman-qos | vman-qos-dual-fp}
number
•
vman-qos
: mark the S-Tag dot1p and queue the frame according to the original C-Tag dot1p. This method requires half as
many CAM entries as
vman-qos-dual-fp
.
•
vman-qos-dual-fp
: mark the S-Tag dot1p and queue the frame according to the S-Tag dot1p. This method requires
twice as many CAM entries as
vman-qos
and FP blocks in multiples of 2.
The default is: 0 FP blocks for
vman-qos
and
vman-qos-dual-fp
.
2.
The new CAM configuration is stored in NVRAM and takes effect only after a save and reload.
EXEC Privilege mode
copy running-config startup-config
3.
Reload the system.
reload
4.
Map C-Tag dot1p values to a S-Tag dot1p value.
INTERFACE mode
vlan-stack dot1p-mapping c-tag-dot1p
values
sp-tag-dot1p
value
Separate C-Tag values by commas. Dashed ranges are permitted.
Dynamic Mode CoS overrides any Layer 2 QoS configuration in case of conflicts.
NOTE: Because
dot1p-mapping
marks
and
queues packets, the only remaining applicable QoS configuration is rate
metering. You may use Rate Shaping or Rate Policing.
Layer 2 Protocol Tunneling
Spanning tree bridge protocol data units (BPDUs) use a reserved destination MAC address called the bridge group address, which is
01-80-C2-00-00-00.
Only spanning-tree bridges on the local area network (LAN) recognize this address and process the BPDU. When you use VLAN
stacking to connect physically separate regions of a network, BPDUs attempting to traverse the intermediate network might be
consumed and later dropped because the intermediate network itself might be using spanning tree (shown in the following
illustration).
Service Provider Bridging
783
Summary of Contents for S4048-ON
Page 1: ...Dell Configuration Guide for the S4048 ON System 9 9 0 0 ...
Page 146: ...Figure 14 BFD Three Way Handshake State Changes 146 Bidirectional Forwarding Detection BFD ...
Page 522: ...Figure 87 Configuring Interfaces for MSDP 522 Multicast Source Discovery Protocol MSDP ...
Page 523: ...Figure 88 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 523 ...
Page 528: ...Figure 91 MSDP Default Peer Scenario 1 528 Multicast Source Discovery Protocol MSDP ...
Page 529: ...Figure 92 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 529 ...
Page 530: ...Figure 93 MSDP Default Peer Scenario 3 530 Multicast Source Discovery Protocol MSDP ...
Page 633: ...Policy based Routing PBR 633 ...
Page 777: ...Figure 119 Single and Double Tag TPID Match Service Provider Bridging 777 ...
Page 778: ...Figure 120 Single and Double Tag First byte TPID Match 778 Service Provider Bridging ...