After you enable the port channel, you can place it in Layer 2 or Layer 3 mode. To place the port channel in Layer 2 mode or
configure an IP address to place the port channel in Layer 3 mode, use the
switchport
command.
You can configure a port channel as you would a physical interface by enabling or configuring protocols or assigning access control
lists.
Adding a Physical Interface to a Port Channel
The physical interfaces in a port channel can be on any line card in the chassis, but must be the same physical type.
NOTE: Port channels can contain a mix of Ethernet interfaces, but Dell Networking OS disables the interfaces that are
not the same speed of the first channel member in the port channel (refer to
10/100/1000 Mbps Interfaces in Port
You can add any physical interface to a port channel if the interface configuration is minimal. You can configure only the following
commands on an interface if it is a member of a port channel:
•
description
•
shutdown/no shutdown
•
mtu
•
ip mtu
(if the interface is on a Jumbo-enabled by default)
NOTE: A logical port channel interface cannot have flow control. Flow control can only be present on the physical
interfaces if they are part of a port channel.
NOTE: The system supports jumbo frames by default (the default maximum transmission unit (MTU) is 1554 bytes). To
configure the MTU, use the
mtu
command from INTERFACE mode.
To view the interface’s configuration, enter INTERFACE mode for that interface and use the
show config
command or from
EXEC Privilege mode, use the
show running-config interface
interface
command.
When an interface is added to a port channel, Dell Networking OS recalculates the hash algorithm.
To add a physical interface to a port, use the following commands.
1.
Add the interface to a port channel.
INTERFACE PORT-CHANNEL mode
channel-member
interface
The
interface
variable is the physical interface type and slot/port information.
2.
Double check that the interface was added to the port channel.
INTERFACE PORT-CHANNEL mode
show config
Examples of the
show interfaces port-channel
Commands
To view the port channel’s status and channel members in a tabular format, use the
show interfaces port-channel
brief
command in EXEC Privilege mode, as shown in the following example.
Dell#show int port brief
LAG Mode Status Uptime Ports
1 L2L3 up 00:06:03 Te 1/6 (Up) *
Te 1/12 (Up)
2 L2L3 up 00:06:03 Te 1/7 (Up) *
Te 1/8 (Up)
Te 1/13 (Up)
Te 1/14 (Up)
Dell#
Interfaces
379
Summary of Contents for S4048-ON
Page 1: ...Dell Configuration Guide for the S4048 ON System 9 9 0 0 ...
Page 146: ...Figure 14 BFD Three Way Handshake State Changes 146 Bidirectional Forwarding Detection BFD ...
Page 522: ...Figure 87 Configuring Interfaces for MSDP 522 Multicast Source Discovery Protocol MSDP ...
Page 523: ...Figure 88 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 523 ...
Page 528: ...Figure 91 MSDP Default Peer Scenario 1 528 Multicast Source Discovery Protocol MSDP ...
Page 529: ...Figure 92 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 529 ...
Page 530: ...Figure 93 MSDP Default Peer Scenario 3 530 Multicast Source Discovery Protocol MSDP ...
Page 633: ...Policy based Routing PBR 633 ...
Page 777: ...Figure 119 Single and Double Tag TPID Match Service Provider Bridging 777 ...
Page 778: ...Figure 120 Single and Double Tag First byte TPID Match 778 Service Provider Bridging ...