Figure 105. Port Monitoring Configurations
Dell Networking OS Behavior
: All monitored frames are tagged if the configured monitoring direction is egress (TX), regardless of
whether the monitored port (MD) is a Layer 2 or Layer 3 port. If the MD port is a Layer 2 port, the frames are tagged with the VLAN
ID of the VLAN to which the MD belongs. If the MD port is a Layer 3 port, the frames are tagged with VLAN ID 4095. If the MD port
is in a Layer 3 VLAN, the frames are tagged with the respective Layer 3 VLAN ID. For example, in the configuration source TeGig 6/1
destination TeGig 6/2 direction tx, if the MD port TenGig 6/1 is an untagged member of any VLAN, all monitored frames that the MG
port TeGig 6/2 receives are tagged with the VLAN ID of the MD port. Similarly, if BPDUs are transmitted, the MG port receives
them tagged with the VLAN ID 4095. This behavior might result in a difference between the number of egress packets on the MD
port and monitored packets on the MG port.
Dell Networking OS Behavior
: The platform continues to mirror outgoing traffic even after an MD participating in spanning tree
protocol (STP) transitions from the forwarding to blocking.
Configuring Port Monitoring
To configure port monitoring, use the following commands.
1.
Verify that the intended monitoring port has no configuration other than no shutdown, as shown in the following example.
EXEC Privilege mode
show interface
2.
Create a monitoring session using the command monitor session from CONFIGURATION mode, as shown in the following
example.
CONFIGURATION mode
monitor session
monitor session type rpm/erpm
type is an optional keyword, required only for rpm and erpm
3.
Specify the source and destination port and direction of traffic, as shown in the following example.
MONITOR SESSION mode
source
Example of Viewing Port Monitoring Configuration
To display information on currently configured port-monitoring sessions, use the
show monitor session
command from EXEC
Privilege mode.
Dell(conf)#monitor session 0
Dell(conf-mon-sess-0)#$source ten 1/1 dest ten 1/2 dir rx
Dell(conf-mon-sess-0)#show c
!
monitor session 0
source TenGigabitEthernet 1/1 destination TenGigabitEthernet 1/2 direction rx
Dell(conf-mon-sess-0)#
Dell(conf-mon-sess-0)#do show monitor session
SessID Source Destination Dir Mode Source IP Dest IP
------ ------ ------------ --- ---- --------- --------
646
Port Monitoring
Summary of Contents for S4048-ON
Page 1: ...Dell Configuration Guide for the S4048 ON System 9 9 0 0 ...
Page 146: ...Figure 14 BFD Three Way Handshake State Changes 146 Bidirectional Forwarding Detection BFD ...
Page 522: ...Figure 87 Configuring Interfaces for MSDP 522 Multicast Source Discovery Protocol MSDP ...
Page 523: ...Figure 88 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 523 ...
Page 528: ...Figure 91 MSDP Default Peer Scenario 1 528 Multicast Source Discovery Protocol MSDP ...
Page 529: ...Figure 92 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 529 ...
Page 530: ...Figure 93 MSDP Default Peer Scenario 3 530 Multicast Source Discovery Protocol MSDP ...
Page 633: ...Policy based Routing PBR 633 ...
Page 777: ...Figure 119 Single and Double Tag TPID Match Service Provider Bridging 777 ...
Page 778: ...Figure 120 Single and Double Tag First byte TPID Match 778 Service Provider Bridging ...