EXEC Privilege mode
show system brief
3
Start diagnostics on the unit.
diag stack-unit
stack-unit-number
When the tests are complete, the system displays the following message and automatically reboots the unit.
Dell#00:09:42 : Diagnostic test results are stored on file: flash:/TestReport-SU-0.txt
Diags completed... Rebooting the system now!!!
Mar 12 10:40:35: %S6000:0 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on stack unit 1
Diagnostic results are printed to a file in the flash using the filename format
TestReport-SU-<stack-unit-id>.txt
.
Log messages differ somewhat when diagnostics are done on a standalone unit and on a stack member.
4
View the results of the diagnostic tests.
EXEC Privilege mode
show file flash://TestReport-SU-
stack-unit-id
.txt
Examples of Running Offline Diagnostics
Trace Logs
In addition to the syslog buffer, Dell Networking OS buffers trace messages which are continuously written by various Dell Networking OS
software tasks to report hardware and software events and status information.
Each trace message provides the date, time, and name of the Dell Networking OS process. All messages are stored in a ring buffer. You can
save the messages to a file either manually or automatically after failover.
Auto Save on Crash or Rollover
Exception information for MASTER or standby units is stored in the
flash:/TRACE_LOG_DIR
directory. This directory contains files that
save trace information when there has been a task crash or timeout.
•
On a MASTER unit, you can reach the
TRACE_LOG_DIR
files by FTP or by using the
show file
command from the
flash://
TRACE_LOG_DIR
directory.
•
On a Standby unit, you can reach the
TRACE_LOG_DIR
files only by using the
show file
command from the
flash://
TRACE_LOG_DIR
directory.
NOTE:
Non-management member units do not support this functionality.
Last Restart Reason
If the system restarts for some reason (automatically or manually), the
show system
command output includes the reason for the
restart.
The following table shows the reasons displayed in the output and their corresponding causes.
Table 97. Line Card Restart Causes and Reasons
Causes
Displayed Reasons
Remote power cycle of the chassis
push button reset
reload
soft reset
reboot after a crash
soft reset
Debugging and Diagnostics
999
Summary of Contents for S3048-ON
Page 1: ...Dell Configuration Guide for the S3048 ON System 9 11 2 5 ...
Page 137: ...0 Gi 1 1 Gi 1 2 rx Flow N A N A 0 0 No N A N A yes Access Control Lists ACLs 137 ...
Page 142: ...Figure 10 BFD Three Way Handshake State Changes 142 Bidirectional Forwarding Detection BFD ...
Page 241: ...Dell Control Plane Policing CoPP 241 ...
Page 287: ... RPM Synchronization GARP VLAN Registration Protocol GVRP 287 ...
Page 428: ...Figure 53 Inspecting the LAG Configuration 428 Link Aggregation Control Protocol LACP ...
Page 477: ...Figure 73 Configuring Interfaces for MSDP Multicast Source Discovery Protocol MSDP 477 ...
Page 478: ...Figure 74 Configuring OSPF and BGP for MSDP 478 Multicast Source Discovery Protocol MSDP ...
Page 483: ...Figure 77 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 483 ...
Page 484: ...Figure 78 MSDP Default Peer Scenario 3 484 Multicast Source Discovery Protocol MSDP ...
Page 745: ...Figure 104 Single and Double Tag TPID Match Service Provider Bridging 745 ...
Page 746: ...Figure 105 Single and Double Tag First byte TPID Match 746 Service Provider Bridging ...